PREPARE THE WALL
1. Disconnect and move freestanding range from cabinet open-
ing to provide easier access to rear wall. Put a thick, protective
covering over cooktop, set-in range or countertop to protect from
damage or dirt.
2. Determine and clearly mark with a pencil the center line on the
wall where the rangehood will be installed.
3. Draw a horizontal line the height of 42 3/16" from the counter
top (as indicated in FIGURE 4).
approximately 18" from the cooking surface ( the
recommended height ).
4. Place the UPPER CHIMNEY MOUNTING BRACKET (E) on
the wall as shown 1/16" from the ceiling, aligning the center notch
with the vertical center line. Mark the wall at the centers of the
holes in the bracket.
5. Place the LOWER CHIMNEY MOUNTING BRACKET (E) on
the wall as shown at 16 1/8" below the upper bracket, aligning
the center notch with the vertical center line. Mark the wall at the
centers of the holes in the bracket.
6. Install the CHIMNEY MOUNTING BRACKETS (E) on the wall
using the MOUNTING SCREWS (D) provided.
7. For the most secure installation, the MOUNTING SCREWS (D)
which mount the CANOPY SECTION (A in FIGURE 1) should be
installed into wood. Mark the wall along the horizontal line 4 9/16"
in from the center line on either side (as indicated in FIGURE 4)
and install the MOUNTING SCREWS into the wall leaving about
1/4" gap between the wall and the head of the screw.
8. For ducted installations, determine and make all necessary
cuts in the wall for the ductwork. Install the ductwork before the
rangehood.
9. Determine the proper location for the Power Supply Cable by
making sure it:
1) Allows the LOWER CHIMNEY COVER to hide the Field
Wiring Compartment.
2) Does not have ductwork blocking your access to the
Field Wiring Compartment. Use a 1 1/4" Drill Bit to
make this hole. Run the Power Supply Cable.
Use caulking to seal around the hole. DO NOT turn on the
power until installation is complete.
This will install the hood
FIGURE 4
INSTALL THE RANGEHOOD
1. Before mounting the CANOPY SECTION, tighten the two
leveling screws located near the CANOPY SECTION mount-
ing points as indicated in FIGURE 5.
FIGURE 5
2. Hook the body on to the MOUNTING SCREWS (D in FIG-
URE 5) and fully tighten the MOUNTING SCREWS.
3. Adjust the leveling screws to level the CANOPY SEC-
TION.
4. For ducted installations, the DAMPER (G in FIGURE 1)
must be attached to the exhaust opening on the top of the
CANOPY SECTION.
Connect the ductwork and seal all
connections with duct tape.
PROCEED TO "FOR ALL INSTALLATIONS" ON NEXT
PAGE