Télécharger Imprimer la page

EUCHNER STP-BI Serie Mode D'emploi page 8

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions
Safety Switch STP-BI...
30
16
<42>
30
With plug connector SR11
61,5
20
53
4
31
74,7
With escape release (short/long actuator shaft)
Figure 4: Dimension drawing for STP‑BI... without insertion funnel and STP‑BI... with insertion funnel
Necessary minimum travel + permissible overtravel
h
Approach direction
Horizontal (h)
Vertical (v)
0,5
For M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
M = 1.5 Nm
M = 0.5 Nm
30
<40>
Auxiliary release with triangu‑
(two triangular keys included)
Always install the escape
release lever on the
recessed side
Short actuator shaft
Long actuator shaft
Actuator S
Actuator L
standard
insertion funnel
24.5 + 5
28.5 + 5
24.5 + 5
28.5 + 5
Auxiliary release
Locking screw
lar wedge
Establish a positive
connection between the
shaft and lever.
8
h
30
19
4
9
Actuating head with insertion funnel
Key to symbols
Guard locking ready for operation
/
Guard locking released
/
4
0,5
M = 0.8 Nm
0,5

Publicité

loading

Ce manuel est également adapté pour:

Stp3-bi-2131 serieStp3-bi-4121 serieStp3-bi-4141 serie