Multigang Installation
Multiple controls can be installed in a multigang wallbox or a series of
interconnected wallboxes for a clean, consolidated appearance. Lutron multigang
faceplates are available to complete the installation. Refer to instruction sheet
supplied with multigang faceplates for installation.
For new installations, controls can be ganged without removing side sections,
but, to reduce the size of the multigang installation or to fit existing wallboxes,
inner side sections must be removed. Because side sections are designed to
dissipate heat, removing them derates the capacity of the control.
Note: When ganging any combination of small and large controls, place all small
controls on one end of the gang and all large controls on the other. Use the
table below to determine the size and rating of each control.
Control Size and Derating Table
Model
Control
Size
Not Ganged
NT-600
S
600 W
NT-1000
S
1000 W
NT-1500
L
1500 W
NT-2000
1
L
1950 W
NT-603P
S
600 W
NT-1003P
S
1000 W
NT-1503P
L
1500 W
NT-1PS
S
20 A
NT-3PS
S
20 A
NT-4PS
S
20 A
NTLV-600
S
600 VA / 450 W
NTLV-600-277
S
600 VA / 450 W
NTLV-1000
S
1000 VA / 800 W
NTLV-1000-277
S
1000 VA / 800 W
NTLV-1500
L
1500 VA / 1200 W
NTLV-603P
S
600 VA / 450 W
NTLV-1003P
S
1000 VA / 800 W
NTLV-1503P
L
1500 VA / 1200 W
NTELV-300
S
300 W
NTELV-600
S
600 W
NTFS-6E
S
6 A
NTFS-12E
L
12 A
NTFSQ
S
1.5 A
NTF-10
S
16 A
NTF-10-277
S
8 A
NTF-103P
S
8 A
NTF-103P-277
S
6 A
NTFTU-5A
S
5 A
NTFTU-5A-277
S
5 A
NTFTU-3AP-277
S
3 A
1
NT-2000 cannot have side sections removed.
2
The maximum lamp wattage is determined by the efficiency of the transformer, with 70%–85% as
typical. For actual transformer efficiency, contact either the fixture or transformer manufacturer. The
total VA rating of the transformer(s) shall not exceed the VA rating of the dimmer.
Note: The Wallbox Requirement Tables on this sheet do not apply for the NT-2000. See
the NT-2000 instruction sheet for the appropriate requirements.
If you have questions concerning the installation or operation of Advance
call the Advance
Technical Support Center. +1.800.372.3331 - U.S.A. and Canada (Monday -
®
Friday, 8 am – 6 pm ET) www.advance.philips.com
Worldwide Technical and Sales Assistance
If you have questions concerning the installation or operation of these
products, call Customer Assistance. Please provide exact model
number when calling.
U.S.A., Canada, and the Caribbean - 1.844.LUTRON1
Other Countries - 1.610.282.3800
Fax - 1.610.282.6311
www.lutron.com/support
4
B B
A
A:
B:
End of Gang
Middle of Gang
500 W
300 W
900 W
700 W
1250 W
1000 W
500 W
300 W
900 W
700 W
1250 W
1000 W
20 A
20 A
20 A
20 A
20 A
20 A
2
2
500 VA / 400 W
300 VA / 200 W
2
2
500 VA / 400 W
300 VA / 200 W
2
900 VA / 700 W
2
700 VA / 550 W
2
900 VA / 700 W
2
700 VA / 550 W
2
1250 VA / 1000 W
2
1000 VA / 800 W
2
2
500 VA / 400 W
300 VA / 200 W
2
2
900 VA / 700 W
700 VA / 550 W
2
1250 VA / 1000 W
2
1000 VA / 800 W
300 W
250 W
500 W
400 W
4.2 A
2.5 A
10 A
8.3 A
1.5 A
1.5 A
16 A
16 A
8 A
8 A
8 A
8 A
6 A
6 A
4 A
3.3 A
4 A
3.3 A
3 A
3 A
Mark X
®
Side Sections Removed
(Derating Required)
Wallbox Gang Size Requirement Table
Number
of Large
Controls
Remove inner side sections from controls. Using pliers, bend side
sections up and down until they break off.
B C B
C:
No Side Sections Removed
2
(Derating Not Required)
2
2
Wallbox Gang Size Requirement Chart
2
2
2
2
2
Number
of Large
Controls
Note: When ganging an even number of small controls with side sections intact,
use gangable 3 in x 2 in (76 mm x 51 mm) wallboxes. Space an additional
wallbox
in (19 mm) apart from the other wallboxes. A
3/4
nipple is recommended as a spacer between wallboxes.
Example: Wallbox arrangement required for ganging 4 small controls with no
side sections removed:
Four-gang
ballasts,
®
wallbox
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year
after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd.,
Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED
WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS
WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION,
OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR
INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL
DAMAGES. LUTRON'S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN
CON NEC TION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT
SHALL NEVER EXCEED THE PUR CHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on
how long an implied warranty may last, so the above limitations may not apply to you.
Lutron and Nova T* are trademarks of Lutron Electronics Co., Inc., registered in the U.S. and other countries.
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
Original is a registered trademark of Hunter Fan Company, Memphis, Tennessee.
Advance and Mark X are registered trademerks of Philips Electronics North America Corporation.
© 2013–2017 Lutron Electronics Co., Inc.
Number of Small Controls
0
1
2
3
0
0
1
2
3
1
1
3
4
5
2
3
5
6
7
3
5
7
8
9
4
7
9
10
11
Remove inner side sections (shaded)
only.
Do not remove outer side sections.
Number of Small Controls
0
1
2
0
0
1
1+1
1
1
3
5
2
4
6
7
3
6
8
10
4
9
11
12
3
in (19 mm) space (use chase nipple)
4
4
5
6
4
5
6
6
7
8
8
9
10
10
11
12
12
13
14
3
4
4
4+1
6
8
9
10
11
13
14
15
in (19 mm) chase
3/4
Single-gang
wallbox

Publicité

loading