Single-Pole Preset Dimmer
Incandescent
Single-Pole: AY-600P & AY-10P
TG-600P & TG-10P
Rated at: 120VAC, 60Hz; 600W or 1000W
(Depending on model)
Important Notes
1. CAUTION: Use "AY-" or "TG-" models only with permanently-
installed 120V incandescent or halogen fixtures. To avoid
overheating and possible damage to other equipment, do not use
to control receptacles, fluorescent lighting fixtures, motor-driven
appliances, or transformer-supplied appliances. Use "AYLV-"
models only with core and coil (magnetic) low-voltage
transformers. To control solid state (electronic) low-voltage
transformers, use Lutron electronic low-voltage dimmers.
2. CAUTION: Operating magnetic low-voltage fixtures with all
lamps inoperative or removed may result in current flow in
excess of normal levels. To avoid possible transformer
overheating and premature failure, Lutron strongly recommends
the following:
030-538
• Do not operate magnetic low-voltage fixtures without operative
lamps in place.
• Replace burned-out lamps immediately.
• Use magnetic low-voltage fixtures with thermal protection or
fused primary windings to prevent transformer failure due to
excess current.
3. When no "ground means" exists within the wallbox, then NEC
380-9 exception to (b) allows a dimmer without a ground
connection, to be installed as a replacement. For this type of
installation cap or remove the green dimmer ground wire. A
dimmer installed under this exception (NEC 380-9 exception to
(b)) must be provided with a plastic, noncombustible, UL listed
wallplate.
030-538
4. Recommended minimum load is 40 watts.
5. Protect dimmer from dust and dirt when painting or spackling.
6. Dimmer and wallplate screws may feel warm to the touch during
normal operation.
7. For new installations, install a test switch before installing the
dimmer.
8. Install in accordance with all national and local electrical codes.
Multi-Unit Installations
When combining controls in a wallbox, remove all inner side sections prior to wiring (see below).
Use pliers to bend side section up and down until it breaks off. Repeat for each side section to be
removed. Reduction of dimmer capacity is also required. Refer to chart below for maximum
dimmer capacity.
Remove all inner side
sections (shaded).
Do not remove outer
side sections.
Model Number
No sides removed
AY-600P / TG-600P
600W max.
AY-10P / TG-10P
1000W max.
AYLV-600P
600VA/450W max.
Technical Assistance
If you have questions concerning the installation or operation of this product, call the Lutron
Technical Support Center. Please provide exact model number when calling.
(800) 523-9466 (U.S.A., Canada, and the Caribbean)
Other countries call (610) 282-3800
Fax (610) 282-3090
Visit our web site at www.lutron.com
Warranty
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to
place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, or in Mexico, Lutron CN, Ltd., Gabriel Mancera 1041, Col. del Valle 03100,
Mexico D.F. postage prepaid. This warranty is in lieu of all other warranties, express or implied, and the implied warranty of merchantability is limited to one year
from purchase. This warranty does not cover the cost of installation, removal or reinstallation, or damage resulting from misuse, abuse, or damage from improper
wiring or installation. This warranty does not cover incidental or consequential damages. This warranty gives you specific legal rights, and you may have other
rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an
implied warranty may last, so the above limitations may not apply to you.
This product may be covered by one or more of the following U.S. patents: 4,876,498; 4,954,768; 5,262,678; 5,359,231; DES 342,234 and corresponding foreign
patents. Lutron and Ariadni are registered trademarks of Lutron Electronics Co., Inc. © 1999 Lutron Electronics Co., Inc.
Installation
Magnetic Low-Voltage
Single-Pole: AYLV-600P
For installations involving more than one control in a wallbox, refer to
Multi-Unit Installations before beginning.
Rated at: 120VAC, 60Hz; 600VA (450W)
Step 1
Step 2
Step 3
Screw Terminals:
Turn screws counterclockwise to
loosen.
Step 4
1 side removed
2 sides removed
500W max.
400W max.
800W max.
650W max.
500VA/375W max.
400VA/300W max.
WARNING: Turn power OFF at circuit breaker or remove
fuse.
Remove switch mounting screws. Pull switch from wall.
Turn screws
counterclockwise
to loosen.
Disconnect switch wires.
OR
Backwired:
Insert screwdriver and pull wire out.
Prepare wires. Trim or strip wallbox wires to the length
indicated by the strip gauge on the back of the dimmer. Use
the same procedure to wire your new dimmer as was used
with the old switch (see Step 3 and below).
Backwire Holes: Insert wires fully.
NOTE: Backwire holes are for use with
#14 AWG solid copper wire only . For
aluminum wire, consult an electrician.
DO NOT use stranded or twisted wire.
OR
Screw Terminals: Tighten securely.
NOTE: Screw terminals are for use with
solid copper wire only. For aluminum
wire, consult an electrician. DO NOT use
stranded or twisted wire.
Français au verso
Step 5
Wire the dimmer.
• Connect the green or bare
Ground
copper ground wire to the
(Green screw)
green ground screw on the
dimmer (see Important Note 3).
• Connect one of the insulated
wires removed from the switch
to either of the screws (or
backwire holes) on the dimmer.
• Connect the other insulated
wire removed from the switch
to the other screw (or backwire
hole) on the dimmer.
Hot
120V
Ground
60Hz
Dimmer
Light
Neutral
Step 6
Mount and align dimmer. Replace wallplate.
Turn screws
clockwise to start.
Align dimmer and tighten
screws clockwise.
Step 7
Turn power ON.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.