Model Number(s)
Control Type
NT-600
NT-1000
Incandescent
NT-1500
Dimmers
NT-2000
Incandescent
NT-1PS
Switches
Incandescent
NT-3PS
Switches
Incandescent
NT-4PS
Switches
NT-603P
Incandescent
NT-1003P
Dimmers
NT-1503P
NTLV-600
Magnetic Low-
NTLV-1000
Voltage Dimmers
NTLV-1500
NTLV-603P
Magnetic Low-
NTLV-1003P
Voltage Dimmers
NTLV-1503P
NTLV-600-277
Magnetic Low-
NTLV-1000-277
Voltage Dimmers
NTELV-300
Electronic Low-
NTELV-600
Voltage Dimmers
NTFS-6E
Fan-Speed
NTFS-12E
Controls
Quiet Fan-Speed
NTFSQ
Control
Fluorescent
NTF-10
Dimmers
Fluorescent
NTFTU-5A
Dimmers
Fluorescent
NTF-10-277
Dimmer
Fluorescent
NTF-103P
Dimmer
Fluorescent
NTF-103P-277
Dimmer
Fluorescent
NTFTU-5A-277
Dimmer
Fluorescent
NTFTU-103P-277-
xx-CPW0196
Dimmer
Notes
Magnetic low-voltage dimmers: For more information, see Application Note 19: "Guide to Dimming Low-Voltage Lighting," P/N 048019, at www.lutron.com. Operation of a dimmed low-voltage
circuit with all lamps removed or inoperative may result in current flow in excess of normal levels. To avoid possible transformer failure, Lutron strongly recommends the following: Do not
operate dimmed low-voltage circuits without operative lamps in place; replace burned-out bulbs immediately; and use transformers that incorporate thermal protection or fused transformer
primary windings in order to prevent transformer failure caused by excess current.
Electronic low-voltage dimmers: These dimmers are overload-protected. If more than the rated load is applied, power to the circuit will shut off until the dimmer cools. If this happens, remove
excess load from the circuit.
For NTELV- models minimum load is 5 W.
Fan-Speed controls: Use with fans marked "Suitable for use with solid-state fan-speed controls only." Set multi-speed fans to their highest setting before installing controls.
Quiet fan-Speed controls: Do not wire into a circuit with a GFCI breaker or receptacle. Set multi-speed fans to their highest setting before installing controls. Not recommended for use with
Hunter Original Series fans; contact Customer Assistance for suitable controls.
For LED loads, please see the "Report Cards" at www.lutron.com/hilumeled for proper loading of the dimmer.
2
Voltage/
Wiring
Rating
Diagram
120 V~ 60 Hz
1
120 V~ 60 Hz
1
120 V~ 60 Hz
3
120 V~ 60 Hz
4
2 (single-pole)
120 V~
3 (3-way)
60 Hz
4 (4-way)
120 V~
1
60 Hz
2 (single-pole)
120 V~
3 (3-way)
60 Hz
4 (4-way)
277 V~
8
60 Hz
120 V~
8
60 Hz
120 V~ 60 Hz
5
120 V~
60 Hz
1
1.5 A
120 V~ 60 Hz
6
120 V~ 60 Hz
1
277 V~ 60 Hz
6
6 (single-pole)
120 V~ 60 Hz
7 (3-way)
8 A
10 (4-way)
6 (single-pole)
277 V~ 60 Hz
7 (3-way)
6 A
10 (4-way)
277 V~ 60 Hz
8
5 A
277 V~ 60 Hz
9
3 A
Magnetic
Electronic
Incandescent/
Low-
Low-
Halogen
Voltage
Voltage
X
X
X
X
X
X
X
X
X
X
X
X
Approved Load(s)
Lutron
Solid
3-wire
Ceiling
State
fluorescent
Paddle Fan
ballasts or
Fan
LED drivers
X
X
X
Advance
®
Mark X
®
Series
Electronic
Fluorescent
Dimming
Ballasts
X
X
X
X
X
X
X