Troubleshooting - red lion RBSS-75FC Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE

Troubleshooting

Troubleshooting
For the flow control to properly operate the pump system, water must pass through the device every time
water is needed. The water supply to the device and pump system is typically from a municipal or utility
water main line. The device can also operate on a cistern or other non-pressurized water tank, but this
should be located above both the pump and the highest water outlet to ensure water flow through the sys-
tem.
If the flow control or pump has been replaced with a model different than the original and performance is
not as expected, check that the technical features of the components are compatible. Refer to
tions" on page
3.
Problem
Pump fails to start or
restart.
Pump works intermittently.
Pump will not shut off.
10
Probable Causes
Unit not plugged in.
Bad electrical connection.
Tripped electrical circuit breaker/fuse.
Pump obstructed.
No water flow.
Control unit not installed vertically in
proper orientation.
Leaks in suction or discharge line.
Minimum flow of 0.15 gpm not sustained. Increase water use.
Plumbing or check valve leak.
System flow continues above 0.15 gpm.
Device contains debris preventing switch
closure.
Control unit not installed vertically in
proper orientation.
Plumbing or check valve leak.
"Specifica-
Corrective Action
Plug in unit.
Check cords for breaks or cracks. Replacement cords are not avail-
able. Replace unit or contact an electrician.
Check electrical circuit breaker panel.
Check pump and suction line for debris.
Check plumbing and water supply.
Correct installation so that the control device is vertical, with all
writing on the product label in the proper upright position.
Check for leaks by adding soapy water at all joints. If bubbles form,
disconnect joint and fix leaks.
Repair or replace faulty plumbing/check valve.
Confirm that there is no water demand.
Check plumbing system for leak.
Clear debris from unit or plumbing.
Correct installation so that the control device is vertical, with all
writing on the product label in the proper upright position.
Repair or replace faulty plumbing/check valve.

Publicité