Output data
Output
Displacement
Load
with output current
with output voltage
Offset
Residual ripple
General Data
Adjustment range
ZERO pot
Adjustment range
SPAN pot
Gain error
Temperature coefficient
Cutoff frequency
Test voltage
Working voltage
(basic insulation)
20 mA, 5 V, 10 V unipolar/bipolar
and 4 ... 20 mA, 1 ... 5 V and 2 ... 10 V,
calibrated selection
–100 %, –50 %, 0 %, 50 %, 100 % of span
of the selected output range
≤ 12 V
(600 Ω at 20 mA)
2)
≤ 10 mA (1 kΩ at 10 V)
20 µA or 10 mV
< 10 mV
rms
±25 % span of selected
output range
0.33 ... 3.30 x final value of selected
input range (max. V
< 0.25 % full scale (DC)
< 0.005 %/K full scale
3)
> 100 Hz
1.5 kV AC across input and output and power supply
300 V AC/DC with overvoltage category II and
pollution degree 2 according to EN 61010-1
For applications with high working voltages, take measures
to prevent accidental contact and make sure that there is
sufficient distance to adjacent devices or sufficient insulation
between them.
= 200 V)
in
25