Your new Aqua-Pure® Stainless Steel Water Filter can be installed on your hot or cold water line, depending on the filter
cartridge used. Filter can be adapted to various pipe sizes by using reducing adapters on either end. Installation fit-
tings can be either sweated or threaded. Use galvanized fittings for installation on galvanized pipe.
To reduce the risk associated with property damage due to water leakage:
• Installation and Use MUST comply with all state and local plumbing codes.
• Protect from freezing, remove fi lter cartridge when temperatures are expected to drop below 40°F (4.4°C).
• Mount fi lter in such a position as to prevent it from being struck by other items used in the area of installation.
City Water
Meter
Aqua-Pure
Sediment/
Rust Filter
Well Water
Pressure
Tank
Aqua-Pure
Sediment/
Rust Filter
To reduce the risk associated with a hazardous voltage due to an installer drilling through existing electric wiring or
water pipes in the area of installation:
• Do not install near electric wiring or piping which may be in the path of a drilling tool when selecting the position to
mount the fi lter bracket.
GETTING STARTED
CAUTION
Hot Water
Aqua-Pure
AP400SS Scale
Aqua-Pure Taste/
Odor Undersink
Filter
Bypass Section can be installed around unit if desired using
either sweated or threaded valves.
Aqua-Pure Taste/
Odor Undersink
Filter
WARNING
Hot Water
Filter
Heater
Aqua-Pure
Sediment/
Rust Filter