Quick start guide, Frequency converter FU
for Schmalz Blower SB-V and SB-V1 / SGBL-FU
30.30.01.00055
Connection terminals of the top row of the double-decker terminal block:
Terminal
(8) +10V SELV
(7) 0-10V/0-20mA,
Analog In 1
(6) –10...+10V, Analog In 2
(4) RS485 A
(5) RS485 B
(9) GND SELV
PT100 - 1A
PT100 - 1B
PT100 - 2A
PT100 - 2B
(9) GND SELV
DIP switch block 1 with 4 switches
DIP-Schalter 1
DIP-Schalter 2
DIP-Schalter 3
DIP-Schalter 4
DIP switch block 2 with 2 switches
DIP switch 1
OFF
OFF
ON
ON
Relais
Function
14 (24)
12 (22)
NOTE
All control voltages refer to a common reference potential (GND). 24 V can be taken from
the respective terminals. The sum of the currents may not exceed 100 mA.
Seite / Page 16/24
Connection
10V DC fixed voltage output
Analogue input 1 switchable voltage/current
0 – 10 V/2 – 10 V/0 – 20 mA/4 – 20 mA
Analogue input 2, voltage input
Serial interface RS485 line A
Serial interface RS485 line B
Signal earth
Temperature input 1 connection A (PT100)
Temperature input 1 connection B (PT100)
Temperature input 2 connection A (PT100)
Temperature input 2 connection B (PT100)
Signal earth
Setting
Function
OFF
Speed set operation
ON
Controlled operation
OFF
No control via RS485/field bus interface
ON
Control via RS485/field bus interface
OFF
No analogue control
ON
Analogue control
OFF
Pressure mode
ON
Vacuum mode
DIP switch 2
OFF
ON
OFF
ON
Description
Relay 1
AOM
11 (21)
Relay 2
AEM
J. Schmalz GmbH
Aacher Straße 29
D - 72293 Glatten
Tel +49 +7443 / 2403 - 0
Fax +49 +7443 / 2403 - 259
Status 01.2014
http://www.schmalz.com
Index 01
e-mail: schmalz@schmalz.de
Analogue input 1
0 – 10V
0 – 20mA
2 – 10V
4 – 20mA
Aggregated operation message.
Device stands still:
The device is turning at a speed > 0.
Aggregated error message.
Fault-free operation:
Malfunction:
11 - 12
11 - 14
21 - 22
21 - 24