Quick start guide, Frequency converter FU
for Schmalz Blower SB-V and SB-V1 / SGBL-FU
30.30.01.00055
Commissioning
After opening the terminal box cover you will find all the connection terminals of the frequency converter
in the connection room.
Installation plug,
field bus interface
PE connection
Release bridge
Control terminals
Relay
aggregated error message,
aggregated operation message
Rel.1, Rel.2
Terminal
L1, L2, L3
PE
U, V, W
X, Y, Z
Connection terminals of the bottom row of the double-decker terminal block:
Terminal
(1) +24V SELV
(2) Digital 1
Digital 2
Digital 3
(9) GND SELV
(9) GND SELV
(3) 0/2...10V Analog Out 1
0/4...20mA Analog Out 1
0/2...10V Analog Out 2
0/4...20mA Analog Out 2
(9) GND SELV
SELV: Safty Extra Low Voltage
1)
Seite / Page 15/24
Power supply connection
L1, L2, L3
Connection
Mains feeder phase L1, L2, L3
Mains feeder earth line PE
Connection strands motor winding U, V, W
Feeder phase external ventilator phase L1, L2, L3 (optional)
Connection
24 V DC fixed voltage output
1)
Digital input 1
Digital input 2
Digital input 3
Signal earth
Signal earth
Analogue output 1 voltage output
Analogue output 1 current output
Analogue output 2 voltage output
Analogue output 2 current output
Signal earth
Status 01.2014
Index 01
Motor winding
PTC thermistor motor
connection
connection T1, T2
U, V, W
J. Schmalz GmbH
Aacher Straße 29
D - 72293 Glatten
Tel +49 +7443 / 2403 - 0
Fax +49 +7443 / 2403 - 259
http://www.schmalz.com
e-mail: schmalz@schmalz.de
External ventilator
connection
(optional) X, Y, Z
Dip-switch
Block 1 - S1
Dip-switch
Block 2 - S5
Slot for field
bus module