Stove switches off.
Fumes extractor is
Alarm displayed is
damaged
"AlAr dEp"
Possible obstructions of
the combustion air inlet
tube
Pressure sensor/switch
is broken
Electronic circuit board
is broken
Stove switches off.
Excessive chimney
Alarm displayed is
length
"AlAr dEp"
Unfavourable weather
conditions
Stove switches off.
Stove is overheated
Alarm displayed is
"AlAr Sic"
Stove is overheated
The room air recircula-
tion fan is broken
Temporary power
failure
Thermostat is broken
Electronic circuit board
is broken
Wood pellets can burn thanks to the
chimney flue having natural draught.
Have fan replaced immediately (cod.
Com0259) as it can be bad for your
health. By authorized Tectro techni-
cian only
Clean the fresh air inlet tube. (see
picture 5 in chapter D.7.)
Replaced the pressure switch code
COM0233. By authorized Tectro tech-
nician only
Replace the electric circuit board code
COM0231. By authorized Tectro tech-
nician only
Call an chimney expert to verify if the
chimney is according to the law.
Call authorized Tectro technician to
verify whether chimney is suitable for
the stove.
When there is a very strong wind a
negative depression to the chimney
can occur. Verify and start the stove
again.
Too high room temperature. Open
doors to other rooms. If the problem
continues call authorized Tectro tech-
nician
Let the stove cool down and stoke it
again. If the problem continues call
authorized Tectro technician
Replace the fan, code COM0268. By
authorized Tectro technician only
A voltage failure during the functio-
ning of the stove causes an overhe-
ating of the internal stove. Let the
stove cool down and stoke it again.
Replace the thermostat, code
COM0238. By authorized Tectro tech-
nician only
Replace the electronic circuit board.
Code COM0231 By authorized Tectro
technician only