EMPTY INTERNAL WATER CONTAINER
Under extreme (environmental) circumstances it may be necessary to empty the
internal water container regularly. When the internal water container is full the
beeping. The unit will switch off automatically. To empty the water container do
the following:
G
DEHUMIDIFICATION
If the unit will be used mainly as dehumidifier, do not connect the exhaust hose
9 and let the warm air return in the room. Continuous drainage is then necessary
and more efficient. You must, however, use a water drain tube, placing its
discharge end at a suitable drainage point.
G
MAINTENANCE
G
Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol,
detergents or other cleansing solutions. For maintenance of the filters, refer to
Chapter D "Air Filter".
G
H
STORAGE
4
86
K light will flash and the display shows E2. Touch any button to stop the
Do not move the unit. Drastic movements can cause water leakage.
Switch off the unit and remove the plug from the wall outlet.
Place a pan or appropriate tray on the floor underneath the drain hole.
Remove the drain knob and rubber plug 8 from the drain tube and let the
water run out. (± 0.8 litres).
Replace the rubber plug 8 and the drain knob and switch on the unit. The
warning light
K should be off and E2 disappears.
NOTE!
When the air conditioner is in use, under normal circumstances the
condensed water will be drained through the air outlet-tube.
WARNING!
Switch off the unit and remove the electrical plug from the mains
before cleaning the appliance or filter, or before replacing the filters.
NOTE!
Never use the air conditioner without screenfilter.
Empty the internal water container (refer to Chapter F)