Installation and User Manual HELO CAVA / HELO ROXX DET
Power Heater connection
cable H07RN-F/
60245 IEC 66
kW
mm
400 - 415V 3N~
6,0
5 x 1,5
9,0
5 x 2,5
Table 2 Connection cable and fuses

3.7. Locating the connecting box for the connection cable in the sauna room

A = Specified minimum safety clearance
1. Recommended location for the connecting box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The connection box must be clear of
obstacles. When installing the connection box to zones 2 or 3, refer to the instructions and regulations of the local energy
supplier.
Fuse
Heater connection Fuse
cable H07RN-F/
60245 IEC 66
2
A
mm
230 V 3~
3 x 10
4 x 2,5
3 x 16
4 x 6
A
Image 5 Location for the connection box
Heater connection
cable H07RN-F/
60245 IEC 66
2
A
mm
230 - 240V 1N~ / 2~
3 x 16
3 x 6
3 x 25
-------
A
3.
1.
2.
Fuse
2
A
35
------
12