Télécharger Imprimer la page

HeatStar HSAG-40 Instructions D'utilisation Et Manuel Du Propriétaire page 17

Publicité

Les langues disponibles

Les langues disponibles

SECTION 7
Wiring
Heaters are normally controlled by thermostats. Line voltage
thermostats are wired directly (see Figure 15), 24V thermostats
are wired directly by finding and removing the jumper wire on the
back of the burner box and wiring the thermostat to the terminals
(see Figure 16). Heaters must be grounded in accordance with the
National Electric Code ANSI/NFPA- 70 or current Canadian Electrical
Code, CSA C22.1. Heaters may also be controlled with a manual line
voltage switch or timer switch in place of the thermostat.
FIGURE 15: Line Voltage Thermostat Wiring
Black
T
Black
White
T
White
Green
120v – 60 Hz
Supply Circuit
Green
120v – 60 Hz
Supply Circuit
FIGURE 16: Low Voltage Thermostat Wiring
Black
White
Black
Green
120v – 60 Hz
White
Supply Circuit
Green
120v – 60 Hz
Supply Circuit
FIGURE 17: Heatstar AG Burner Internal Wiring
If any of the original wire as supplied with the
appliance must be replaced, it must be replaced with
wiring material having a temperature rating of at
least 105°C and 600 volts.
Each burner must be electrically grounded in
accordance with the National Electric Code ANSI/NFPA
- 70 or current Canadian Electrical Code, CSA C22.1.
Thermostat
Pressure Switch
RED
YELLOW
BLACK
L1
T1
Line
Load
Blower Motor Cavity
WHITE
WHITE
N
GREEN
Earth Ground
Chassis Wiring Is 18 AWG / 105 Degrees C / @ 600 Volts
Igniter Wire Is 16 AWG / 25 KVDC / 10 KVDC
Crimp Caps Are # CE5 / 105 Degrees C
Burners
(Maximum – 2 per Thermostat)
Burners
(Maximum – 2 per Thermostat)
H
H
N
N
Burners
(Maximum – 1 per Thermostat)
H
Burners
(Maximum – 1 per Thermostat)
N
H
T
N
T
Igniter & Flame Sense
IGN
BLUE
RED/YELLOW
RED
BLACK
BLACK
YELLOW
C1
M
CONTROL BOARD
GV
GREEN
Replace Any Wiring With Same Ratings
All Quick Connects Are Fully Insulated (Except Igniter)
Enerco | Heatstar AG Series Heater
FIGURE 18: Heatstar AG Burner Internal Wiring Ladder Diagram
L1
T'STAT (Optional)
JUMPER (Optional)
FC-
FC+
GND
LED
V2
24 VAC
L1
IND
NC
V1
PSW
TH
E-17
Operating Instructions and Owner's Manual
L1
PCB
IND
PCB
IGNITER/FLAME SENSOR
IGN
PCB
T1
PRIMARY - 120V
SECONDARY - 24V
24 VAC
PCB
TH
PCB
PRESSURE SWITCH
V1
GV
PCB
N
M
BURNER
PSW
PCB
V2
GND
PCB
Earth &
Chassis Ground

Publicité

loading

Ce manuel est également adapté pour:

Hsag-60Hsag-80Hsag-100Hsag-125Hsag-150Hsag-175