VII. - FORCED CONVECTION. (Mod. H03 TURBOCONVECTOR)
A. - Installation
Ventilator
Install the ventilator in the preferred
position (see fig. 13) using the screws
provided, if position 2 or 3 is chosen
remove the top and place it together
with the fibre joint in the window of
position 1.
In both cases, previously installed in the
cowling vibration of 6x80 screwprovided
Set position
by two
accompany
pressedhome against the cast
side as described in fig.8izqda.
For
any
positions fan pinch NTC temperature pr
obe between the fan frame and one of
said fastening screws (recommended in
one
of
the
see fig. 8dcha).
Then connect the circuit to the power
supply. Check that the system operates
properly as explained in Section B.
Fig. 8izqda: fan window in position 2 or 3, installed vibration screw. Fig 8dcha: fan tied around his
window with NTC probe caught between screw and fan frame
Chimney
Connect the H03 TURBO-CONVECTOR Wood Burner to the chimney following the
instructions contained in chapter II.
Forced convection
The air outlets from the convection chamber must be connected using flexible tubes to the
areas where you wish to direct this flow, either to the room where the wood burner is installed
or to other adjacent rooms.
The H03 TURBOCONVECTOR wood burner will be supplied with half of the outlets closed
with caps (see fig. 13). This can be used according to the number of outlets that you need.
Never leave an outlet open inside the casing, as convection efficiency will be lost.
nuts that
it, leaving the set
iron
of the
upper
screws,
Air outlet to
other rooms
Air outlet to
other rooms
Air outlet
to the room
Air inlet for
THe fan.
Fig.-7 – Guide Diagram
orientativo
24
Air outlet to
the room
Natural lining
convection outlet
Chimney
conduit