5. INSTALLATION
Prior to commissioning, check the pump
for possible external damages (e.g.
transport damages) in order to prevent
accidents with electrical current.
If the pump shall be inserted into a pit or a duct,
its dimensions must allow the float switch to
move freely. When the water level rises with the
float floating to the top, so the pump will turn on
and pump off the water until such a low water
level has been achieved that the float turns off the
pump again.
The heights required by the float to start and stop
the pump can be changed by moving the float
cable through its fixing eyelet.
The inlet screen must not be clogged by mud and/
or fibrous media.
Even an automatically operating device,
such as a submersible pump, must not
be operated for a long period of time
without supervision.
Non-return valve : In order to prevent liquid
from flowing back from the hose / piping after
switching off the pump, the enclosed check valve
Ⓑ can be installed :
- hold the valve by the cover
- place the valve, with the cap facing upwards, in
the discharge connection
6. MAINTENANCE
Disconnect the electrical supply before
carrying out work on the unit!
Maintenance consists of checking and cleaning
the sieve :
- Turn over the pomp
- Undo the screws
- Clean the sieve
- Reassemble sieve by following the opposite
procedure.
7. MALFUNCTIONS: CAUSE AND
TROUBLESHOOTING
Malfunction Cause
1. Motor
- Supply voltage
does not
missing or wrong
rotate
- Faulty connection
- Defective power
cable
- Impeller blocked
- Activated
motor protection
(overheating,
blockage, voltage
error or other defect)
- Float suspended
- Motor defective
2. Motor
- Impeller clogged or
rotates, but
worn
does not
- Discharge pipe
convey
clogged/hose kinked
- Sieve clogged
3. Feed
- Pump not properly
volume too
ventilated (air bubble
low
int the housing)
- Discharge pipe
dimensioned too
small
4. The pump
- Water too dirty
stops too
quickly
- Pump blocked
- Thermical
protection on
8. GUARANTEE
SANISUB STEEL is guaranteed for 2 years for
parts and labour, subject to correct installation
and use of the unit.
5
UK
FR
Troubleshooting
- Check power
supply
- Correct
connection
- Replacement
(Customer
service)
- Clean
- Check, inform
customerservice
- Change the
position of the
pump
-Replacement
(Customer
service)
- Clean/Replace
- Clean/Remove
kinks
- Clean
- Remove air by
tilting the pump
- Min. diameter of
25mm
- Unplug and
clean
- Unplug and
cleanr
- Check the water
temperature (see
4. Technical data)