RELAIS
K1
- Common relay both during opening and closing.
K2
- Power relay which enables closing
K3
- Power relay which enables opening.
K4
- Relay controlling the 12Vac electric lock.
K5
- Relay controlling the light signalling that the gate is open.
CONNECTOR J1
A fixed connector which supports the microprocessor logic.
PLUG J2
2
- Stop push-button (n.c.).
K
- Single pulse contact (n.o.).
7
- Contact of the limit switch which interrupts closing (n.c.).
4
- Contact of the limit switch which interrupts opening (n.c.).
9
- Push-button opens (n.o.).
11
- Push-button closes (n.o.).
E
- Contact given by the safety devices in the opening phase (n.c.).
B
- Contact given by the safety devices in the closing phase (n.c.).
10
- Photo cells contact (n.c.).
8
- Common of the contacts.
PLUG J3
FN
- 230V 50/60 Hz power supply.
- Earth terminal.
M1
- Single phase motor connection.
U
- Common wire.
V1-W1
- Inverters
L-L
- Flashing light feed out-put 230V (40W max.).
CONNECTOR J4
Connector for housing R.I.B. radio receivers.
PLUG J5
A*
- Common wire for power supply.
A
- 24Vac power supply for photo cells.
D+D-
- 12Vdc power supply for accesssories.
SL
- Gate open light LED power supply.
1
- 12Vac electric lock power supply.
CHB
- Radio channel B contact output (n.o.).
CHC
- Radio channel C contact output (n.o.).
CONNECTOR J6
When it is in the ON position (dip-switch 8), it supplies a courtesy lamp for 3 minutes (max. 40W) by means of an optional card (box auxiliary
activation code ACQ9070).
The green LED on the card signals that it is fed.
The red LED on the card signals the relay is enabled for the box light..
In the "OFF" position (dip-switch 8), the optional card relay will give a 1" pulse (examples of applications: timed relay control, garden lights, access
to garage, underground corridors, etc.).
N.B.: Do not insert the automatic closing timer on the card (ACQ9050), since the automatic closing function is managed by the microprocessor, see
trimmer P3 or the "automatic closure" paragraph.
S1
Safety microswitch (only enabled for central units/garcases in small containers mod.K).
PLUG "ANTENNA"
Plug to connect the aerial's shielded cable (type RG58-52).
The central wire must be fixed in the clamp with cut screw, and the cable with the external copper braiding must be fixed in
the clamp with cross screw.
NOTE: Be sure that the central wire of the cable does not enter in contact with the external copper braiding because this would prevent the
functioning of the aerial.