ELECTRONIC PANEL FOR THE CONTROL
Important - to check operation of the control unit faster :
The yellow leds indicate very low voltage power supplies.
The green leds indicate pulses emitted by commands and they are normally not illuminated (they should come on only when a command is
transmitted).
The red leds indicate the contacts of safety devices and limitswitches and they are normally all illuminated (they should switch off only if the safety
devices or the limit switches operate).
LEDS
L1
- (Yellow) Signals that there are voltages of 24Vdc and 12 Vdc.
L2
- (Red)
Automation in the closing phase.
L3
- (Green) Automation in the opening phase.
L4
- (Red)
Signals contact given by the stop push-button (n.c.).
L5
- (Green) Signals contact given by the single pulse push-button or by the radio control (n.o.).
L6
- (Red)
Signals contact given by the limit switch which interrupts closing (n.c.).
L7
- (Green) Signals contact given by the opening push-button (n.o.)
L8
- (Green) Signals contact given by the closing push-button (n.o.)..
L9
- (Red)
Signals contact given by the safety devices during opening (e.g. radio strips, pneumatic strips, mechanical strips or photostrips)
(n.c.).
L10
- (Red)
Signals contact given by the safety devices during closing (e.g. radio strips, pneumatic strips, mechanical strips or photostrips)
(n.c.).
L11
- (Red)
Signals contact given by the photo cells (n.c.).
L12
- (Red)
Signals contact given by the opening limit switch (n.c.).
L13
- (Yellow) Signals that the microprocessor assembled on the auxiliary circuit is fed (5Vdc).
TRIMMERS
P1
-Regulates the operating time (max. 120").
P3
-Regulates the waiting time before there is automatic closing (max. 120").
SW1
8-WAY DIP-SWITCHES (ON AUXILIARY CIRCUIT)
DIP 1
- If set to "OFF", it does not enable the intervention of the photocells during opening.
DIP 2
- If set to "OFF", it does not enable automatic closing.
DIP 3
- If set to "OFF", it feeds "L-L" with continuity.
- If set to "ON", it feeds "L-L" intermittently.
DIP 4
- If set to "OFF", the flashing light and the motor are fed at the same time.
- If set to "ON", the flashing light starts 3 seconds before the motor.
DIP 5
- If set to "OFF", the radio pulse and the single pulse operate as is specified in the "radio control operation" paragraph.
- If set to "ON", after the gate has started opening, the radio pulse or single pulse will no longer be effective (there will no longer be the
stop), until the limit switch is reached or until the end of the opening operating time.
Whilst the gate closes again, the radio pulse or single pulse stop the movement of the gate and then start it again automatically in the
opposite direction, after a predetermined pause.
DIP 6
- If set to "OFF", all the functions operate automatically.
- If set to "ON", it operates with somebody present (see "operation with somebody present" paragraph).
DIP 7
- In set to "ON" it excludes working time off the electric lock.
DIP 8
- If set to "ON", it enables the optional "box activation" card (ACQ9070) for 3 minutes.
- If set to "OFF", for just one second (1").