3.3.3 SW2 settings
Door opener time: the positions of dip-switches 1 and 2 (DOOR TIME) determine the activation time of the
pedestrian gate lock.
Dip 3
Dip 4
Dip 5
Dip 6
Auto-on restriction with even ID code: DIP switch 3 allows the user group with even ID code to use the
video auto-on function only on door units with even address ID=0 (if secondary) or ID=2; consequently,
users with odd ID code may used the auto-on function in video mode only on door units with odd address
ID=1 (both main and secondary) or ID=3.
During door unit auto-on, the audio line will be also available (if the user started a conversation) in addition
to the door opener service.
The service works with main and secondary video door units, except for the case of MAIN door unit with
ID=0 that all users must be able to use in auto-on mode.
Call button address management: the position of the DIP switch 4 can be used to change the call address
of the door unit button. The function must only be changed on the single-family panel Ref. 1784/1.
Door status or Letterbox: DIP switch 5 can be used to manage input SP for the DOOR STATUS or
LETTERBOX functions (future implementation).
50/60 Hz camera: DIP switch 6 can be used to set the frequency of the camera.
3.3.4 SW1 rotary switch
The position of the rotary switch determines a guaranteed conversation time, i.e. extends the busy time
from the answer onwards.
The busy time is equal to the reply time (max. 60s) added to the guaranteed conversation time.
The guaranteed conversation time must be programmed in the same way for all system call
stations.
18
ON
1 second
1
2
3
4
5
6
ON
3 seconds
1
2
3
4
5
6
Auto-on restriction
Address management
Door status
or Letterbox function
Camera
SW2 DIP switch 4
OFF
ON
Pos. 0
1 second
Pos. 1
10 seconds
Pos. 2
20 seconds
Pos. 3
30 seconds
Pos. 4
40 seconds
ON
6 seconds
1
2
3
4
5
6
ON
9 seconds
1
2
3
4
5
6
ON
Service
not active
1
2
3
4
5
6
ON
Service
not active
1
2
3
4
5
6
ON
Door Status
1
2
3
4
5
6
ON
50 Hz
1
2
3
4
5
6
Call
Apartment station with code 0
Apartment station with code 1
Pos. 5
50 seconds
Pos. 6
60 seconds
Pos. 7
70 seconds
Pos. 8
70 seconds
Pos. 9
70 seconds
ON
Service
active
1
2
3
4
5
6
ON
Service
active
1
2
3
4
5
6
ON
Letter Box
1
2
3
4
5
6
ON
60 Hz
1
2
3
4
5
6
DS1784-001

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mikra2 1784/2

Table des Matières