Installation and Wiring Instructions for the SOLO Plus SELV Bathroom Extract Fan.
IMPORTANT:
READ THESE INSTRUCTIONS
BEFORE COMMENCING THE
INSTALLATION
DO NOT install this product in areas where the following may be present or occur:
•
Excessive oil or a grease laden atmosphere.
•
Corrosive or flammable gases, liquids or vapours.
•
Ambient temperatures higher than 40°C or less than –5°C.
•
Possible obstructions which would hinder the access or removal of the Fan.
SAFETY AND GUIDANCE NOTES
A. All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate standards of your country
and MUST be installed by a suitably qualified person.
B. The electrical supply to this fan is 24v DC SELV from the transformer/controller. This means the fan may be
installed within reach of a person using a fixed bath or shower, i.e. in a nearby wall. However, the fan must not
be placed where it could be submerged in water or regularly exposed to direct water spray, e.g. from a shower
head whether permanently fixed or movable.
C. ONLY CONNECT TOGETHER THE PRODUCTS FROM THE SOLO PLUS SELV RANGE SINCE THE FANS
ARE SPECIALLY DESIGNED TO WORK ON 24v DC AND ARE NOT COMPATIBLE WITH OTHER VENT-
AXIA CONTROLLERS. DO NOT CONNECT MORE THAN ONE FAN TO THE CONTROLLER.
D. The controller must not be installed in a shower cubicle or enclosure. It must be away from direct sources of
water spray and out of reach of a person using a fixed bath or shower. Site away from direct sources of heat.
E. The controller needs free air circulation and must not be covered with any insulating material such as might be
in a ceiling or roof void.
F. The Fan should be provided with a local isolator switch capable of disconnecting all poles, having a contact
separation of at least 3mm.
G. Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating label.
H. The Fan should only be used in conjunction with the appropriate Vent-Axia products.
I. It is recommended that the connection to the fan connector terminals is made with flexible cable.
J. When the Fan is used to remove air from a room containing a fuel-burning appliance, ensure that the air
replacement is adequate for both the fan and the fuel-burning appliance.
K. Where ducted Fans are used to handle moisture-laden air, a condensation trap should be fitted. Horizontal
ducts should be arranged to slope slightly downwards away from the Fan.
L. This appliance is not intended for use by young children or infirm persons without supervision.
M. Young children should be supervised to ensure that they do not play with the appliance.
N. Fans used for tropical climates.
DESCRIPTION
As standard, the SOLO Plus is suitable for panel/wall installations, flush or surface mounting, either in a horizontal
or vertical plane. 100mm ducting (flexible or rigid) can be attached using the supplied adjustable spigot, providing
rear or side exit options. Adaptors for System 25 and System 50 ducting can be used in conjunction with the
adjustable spigot. For wall installations a Wall Kit (25 41 02 White / 25 41 00 Brown) can be used. Please see our
catalogue or web site (www.vent-axia.com) for more information on System 25/50 and for alternative ducting and
termination options.
A. INSTALLATION
SELV CONTROLLER
The controller can be installed surface or recess mounted using the supplied surface mounting box or a standard
mounting box. Please note that the fixing screws may have to be replaced with screws suitable for the type of
mounting box used.
PANEL MOUNTING (Surface)
1. Cut a 105mm∅ hole through the panel, ensuring that there is sufficient space for the product to be installed
and that the filter can be removed for maintenance.
2. Removing the Front Assembly [A]. Firstly remove the Filter [B] (fig. 2.) by squeezing the clips and pulling. Insert
a small bladed screwdriver into the slots as shown in figure 3 and push gently to release. Lift the front
assembly slowly from the bottom edge ensuring not to damage the sensor cable (TM model only) attached to
the front assembly and Base Housing [C] (fig. 3/4/11.). IMPORTANT: The cable for the PIR sensor (TM