Bulletin 408134 R03 13.06.2016
EPP4 Pressure Regulator
DISPLAY OPTION
Order No.:
P4CG4002 series, P4CN4002 series
Compact and highly readable remote LED display, with
bar and PSI scales.
Connection
-
M12 connector on EPP B connector
-
M8 connector on Display's connector
The display is ready to use.
Specific Oxygen version ref P4C.4051.... Reminder on the oxygen use
This oxygen version reference is designed and assembled taking into account the general rules, the state of
the art, to be applied on components that will be used with oxygen for industrial applications.
This version is using only oxygen compatible materials, but the material type is not the only factor in a typical
self ignition process. Flow speed for example, is a very important factor, and should be limited to 25 m/sec in
the whole application (attention to valve restriction).
Filtration also should be carefully implemented and maintained (a filter partially blocked will increase the flow
speed).
The final user should be familiar with these general rules that must be applied for oxygen applications, and is
responsible of the real conditions of use of our regulators.
Instructions de Montage, Mise en Service & Maintenance
The display is delivered in its own packaging with
its specific manual.
1.5m cable included (M12 – M8)
Easy to fix with its 2 different mounting brackets.
7
Part Mo. 496540
Parker Hannifin Manufacturing Switzerland SA
Fluid Control Division Europe
CH-1227 Carouge-Genève

Publicité

loading

Ce manuel est également adapté pour:

Lucifer epp4 p4cg2 c serieLucifer epp4 p4cn2 c serie