14 AIR CONNECTION
IMPORTANT: CONNECTION PIPING
Use a flexible hose to connect the compressor to the network (not included in the delivery).
15 INSTALLATION
15.1 INSTALLING LOCATION
a
The compressor must be installed on an even surface, bearing in mind the compressor's weight (Cf.
Technical specifications).
The water drain contains traces ofoil.
b
Study the dimensional drawing for the required minimum distances to walls and other machines.
c
Make sure that the compressor room is properly ventilated. The cooling air temperature must be
lower than + 45°C or higher than 0°C. Prevent recirculation of cooling air. If the compressor is
provided with air ducts, observe the required air volume and the max.pressure loss of the ducting.
Observe also the possibility to clean the cooler (Cf. Technical specifications).
Please note that in case of an air-cooled compressor, almost the whole compressor input
power is transferred to the cooling air as heat.
The compressor should not be installed in location with concrete, silica or other dust in the
atmosphere without special intake pre-filtering: IN CASE OF DOUBTS PLEASE CONTACT
AUTHORIZED DISTRIBUTOR.
Outside installation is not allowed:
0° C
15.2 INITIAL CHECKS
After removing the compressor from its packaging, before proceeding with installation, please verify that no
damages occurred during transportation.
Packaging materials such as wood, nails and plastic sheet could be dangerous for children and
should not be left within their reach.
a - Check that all the fuses in the electrical board are properly fitted and tightened.
b - Check that the protection main nuts are tightened and the screw fixed.
2-12