5.5 Wiring diagram
L
N
230V
32
50Hz
16
44
130
A
Attention: Before connecting the room thermostat or the remote timer
trol, remove the jumper on the terminal block.
16
Fan
32
Heating circulating pump
42
DHW temperature sensor
44
Gas valve
72
Room thermostat
82
Detection electrode
95
Diverter valve
130
Hot water tank circulating pump
138
External probe
139
Remote timer control
186
Return sensor
188
Ignition electrode
246
Pressure transducer
256
Modulating heating circulating pump signal
278
Double sensor (heating + safety)
341
Exchanger probe
A
ECO/COMFORT contact