Lenze E84AZESR LD Serie Instructions De Montage page 41

Filtre antiparasite
Masquer les pouces Voir aussi pour E84AZESR LD Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operating conditions
Ambient conditions
Climatic
Storage
Transport
Operation
Permissible
humidity
Pollution
Site altitude
Mechanical
Vibration
resistance
Electrical
Mains connection
Power system
TT, TN
(with
earthed
neutral)
IT
Mounting conditions
Mounting place
Mounting position
Free space
EDK84AZESR DE/EN/FR/ES/IT 3.0
IEC/EN 60721−3−1
IEC/EN 60721−3−2
IEC/EN 60721−3−3
EN 61800−2
EN 61800−5−1
EN 61800−5−1
Germanischer Lloyd,
general conditions
l
General data and operating conditions
1K3 (−25 ... +55 °C)
2K3 (−25 ... +70 °C)
3K3 (−10 ... +55 °C)
Humidity class 3K3 (without condensation;
average relative humidity 85 %)
Degree of pollution 2
< 4000 m amsl
Above 1000 m amsl reduce the power by
5 %/ 1000 m.
Acceleration resistant up to 1 g
Operation is permitted without any restrictions.
Max. mains voltage 400 V!
Observe instructions for special measures!
In the control cabinet
Vertical
^ 44
Technical data
4
41

Publicité

Table des Matières
loading

Table des Matières