Important; Electrical Requirements - Summit BIM44 G Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating temperature should be
Normal operating water temperature should be between 41°F (5°C) and 90°F
(32°C). Operation of the ice maker for extended periods out- side of these
normal temperature ranges may affect production capacity.
It is strongly recommended that a water filter be used.
proper type, can remove taste and odors as well as particles. Some water is very hard,
and softened water may result in white, mushy cubes that stick together. Deionized
water is not recommended.
The ice maker must be installed with electrical and water connections in accordance
with all state and local codes.
The unit should be located on a firm and level surface. It is important for the ice maker
to be leveled in order to work properly. If needed, you can adjust the height of the ice
maker by revolving the caster. See the Leveling the Ice Maker section.
A standard electrical supply (115V AC only, 60Hz, 15A), properly grounded in
accordance with the National Electrical Code and local codes and ordinances, is
required.
IMPORTANT: Do not kink or pinch the power supply cord between the icemaker and wall
or cabinet.

Electrical Requirements

Plug into a grounded 3-prong outlet.
Never remove the ground prong from the plug.
Never use an adapter.
Never use an extension cord.
Failure to follow these instructions can result in fire, electrical
shock or death.
within the range of normal room temperatures.
Electrical Shock Hazard
9
A filter, if it is of the

Publicité

Table des Matières
loading

Table des Matières