6
Fitting the BS-USV
6 .1
Installation and Initial Start-Up of the BS-USV
Never clamp the wires of the power input I / P-L and I / P-N with those of the power output O / P-L and O / P-N .
This may damage the device beyond repair .
1.
Optimise the motor current on the door control. To do this, set P 910 = 2 to view the motor current in the display.
Use P 140 to set the motor current to the minimum depending on the normal mains voltage. After the motor
current has been optimised, all door functions must be available under all circumstances.
2.
Set the operating parameter required for UPS operation on the control BK 150 FUE-H / FUE-1: A.490 = 1.
3.
Switch off door control. Disconnect the mains connection for the door control from the on-site power supply.
4.
Fit the power input connections I/P-L to K1:44 and I/P-N to K1:54.
5.
Fit the emergency power output connections O/P-L to K1:R1 and O/P-N to K1:R3.
6.
Plug cable (4) to the batteries.
7.
Switch on the power supply – see wiring diagram.
8.
Turn on the BS-USV with the main switch (1). the BS-USV beeps, the green LED (5) indicates that there
is a power supply.
9.
Switch on the door control and perform initial start-up of the door in accordance with the instructions.
–
The batteries are partially charged when the BS-USV is shipped. A full charge and guaranteed function is only
possible after 12 h charging time.
018767 / BK-USV / BS-USV RE / 10.2015
ATTENTION
7
Dismantling / fitting trap guard BS-USV
OFF
3S1
OFF
O N
OFF
8
Changing Batteries
(see Figure 1) BK-USV
1.
BK-USV switch it off with the stand-by switch
X2) and then the mains (X0).
2.
Remove the battery connection cable. Follow the order:
3.
Replace all batteries by new ones.
➃
➂
➁
4.
Reconnect in the opposite order:
–
–
5.
Connect the BK-USV with the door control (CEE plug X2 and BK-USV connection cable with 4-pin WX1 / X1 plug).
6.
Switch on the BK-USV using the main switch
7.
Perform an initial start-up of the door control in accordance with the instructions.
➀
and then completely disconnect it from the door control (X1 and
➁
➂
➃
–
–
.
.
➀
➄
, the UPS beeps, after a short while the LED
ENGLISH
is on.
13