Troubleshooting

Troubleshooting
Symptom
Air escapes audibly at the
fastener driving tool's
safety valve.
Air escapes audibly at the
connection for the
cartridge.
No release possible
If the malfunction still cannot be remedied, contact your specialist
dealer or the manufacturer (see page 18).
14
Possible cause
The operating pressure
is too high; the fastener
driving tool is damaged.
The cartridge was
loosened by shock.
The gaskets on the
connections for the
cartridge are defective.
The operating pressure
is too low.
Remedy
 Separate the cartridge from
the fastener driving tool
(see page 10).
 Send cartridge and device
to PREBENA via a
specialist dealer
(see page 18).
 Screw the cartridge hand-
tight into the connection
(see page 9).
 Connect new cartridge
(see page 9).
 Send cartridge to
PREBENA via a specialist
dealer (see page 18).
If the problem persists:
 Send the fastener driving
tool to PREBENA via a
specialist dealer
(see page 18).
 Connect new cartridge (see
page 9).