STARTING CYCLE
1st Lighting (new appliance and whenever the pellet container has been completely emptied
-Put the fuel into the container and switch on the appliance
-In case the display is signalling an alarm keep the push button P4
pressed
-In case the display is signalling "Final cleaning" wait until on the
display appears "Off" (approx. 15 minutes)
- Appliance in switched off condition display "OFF"
- Push on P3 to get access to the programming menu.
- Push P5 to go on MENU 07
- Push P3 to go to the menu load initial
- Push on P1 to activate the continuous charge of fuel.
- Once the pellet has started to fall into the
burner basket press on push button P4 to stop
the fall of fuel into the burner basket.
- Empty the burner basket from the fuel and put it again in its correct
place.
- Push P4 and keep it pressed for few seconds until the display reports
the start of the lighting
NORMAL STARTING CYCLE
Push P4 and keep it pressed for few seconds
The appliance begins an automatic cycle to effect the lighting, this cycle is composed by 3
phases, which are shown on the display :
1-START (duration approx. 2min.)
(lighting element heating)
3-FLAME LIGHT (duration 5 min)
(burner stabilization)
IT IT IT IT- - - - GB
GB- - - - FR
GB
GB
2-LOAD PELLET (max. duration 18/20 min)
(fuel loading)
Once the lighting phase has been completed,
the appliance starts working normally
55/140
FR- - - - ES
ES mod. 540 VT – 540N VT
FR
FR
ES
ES