Preliminary operations
Take away the packing
•
Before installation, check the appliance integrity. In case of doubt, do not use the
•
appliance and call the dealer.
Packing materials is for recycle, getting it in the specify container
•
Appliance positioning
The installation room should have :
•
− A suitable floor for appliance weight. Should the existing construction not satisfy this
requirement, necessary measurements must be taken (I.e. a plate for the distribution of the
weight)
− A suitable floor for appliance calorific radiation, which grants against fire risks.
− The installation of the appliance should grant an easy access for the cleaning operations of
the appliance itself, as well as of gas exhaust ducts and of the chimney.
− A minimal distance from flammable materials (see security distances)
− The room must be continuously ventilated according to the local rules.
− It's prohibited to install the equipment into sleeping rooms, bathroom or where another
heating equipment ( without an independent air supply ) is just installed.
− It's prohibited product positioning in environments with explosive atmosphere
FLOOR PROTECTION
The equipment must be installed on a non–combustible surface. In case of flammable floor (as
wood, moquette, etc.) is necessary to prepare a protective base of the floor (sheet steel,
ceramic or other) with the following dimensions:
Hold up in front ≥ 500 mm;
−
Hold up back
−
SECURITY DISTANCES
From NOT combustible object :
•
A > 500 mm B > 100 mm C > 100 mm D > 1000
−
From combustible object and from principal wall in reinforced concrete :
•
A > 1000 mm B > 200 mm C > 200 mm D > 1000
−
The minimal distance between the appliance and every objects over it
•
must be at least 1 meter.
Mod. 540 VT
≥ 100 mm
Mod. 540N VT
40/140
IT IT IT IT- - - - GB
GB- - - - FR
FR- - - - ES
ES mod. 540 VT – 540N VT
GB
GB
FR
FR
ES
ES
Hold up lateral ≥ 300 mm;