To guarantee a perfect combustion it's
necessary to preserve the wood in a dry
and clean place.
The wood thermic output is related to its
humidity in %. (see the schedule ).

2.3 Starting

The appliance should set at work only after having completed the following operations:
complete assembling, connection to exhaust fumes duct and to the heating plant. A new
appliance needs to complete the drying process of the paint. During the first heatings you
can notice the following situations:
- During the first ignitions the appliance may exhale bad smell. We suggest a good
aeration of the room till bad smells have been eliminated.
- The complete drying process will be obtained after some heating operations
The equipment is a wood stove with a functioning as Normative EN 13240. Thanks to
combustion chamber structure, the equipment has an high calorific efficiency. The cover
is complete in enamelled steel, in the visible models the fire and oven door has a
ceramic glass. The normal model has the fumes connection on right but it's available
also the left model.
COMBUSTIBLE LOADING
The appliance should be loaded manually during the functioning.
The loading of combustible should be done when the flame is minimum to avoid
combustion products or fumes outlet from the fire door.
To open the fire door, employ the fixture enclosed.
STARTING AND FUNCTIONNING
N.B. For starting never use : alcohol, fuel, or others liquid combustibles.
In case of starting during particular cooling days or in a condition of low pressure, it's
advisable to heat the flue before the starting, burning inside it some pieces of papers
For the combustible quantities please read the "Technical Data " ..
IGNITION
To arrange on foyer a cube-lighting or a small quantity of paper, around 0,5 kg of wood
in small pieces. Open entirely the prime and secondary air, light the paper and close the
foyer door.
When the appliance is completely lighted, add some larger wood pieces. Repeat this
operation till when the appliance has reached the " Hourly Charge " as indicated in the
technical details, than regulate the prime and secondary air as indicated in the chapter
Regulations
The equipment should be loaded when the flame i slow to avoid fumes or combustion
products escape.
During equipment functioning it's advisable to employ the ash-grater to clean the foyer
from ash and residuals.