To guarantee a perfect combustion it's
•
necessary to preserve the wood in a dry
and clean place.
The wood thermic output is related to its
•
humidity in %. (see the schedule ).
2.3 Starting
The appliance should set at work only after having completed the following operations:
•
complete assembling, connection to exhaust fumes duct and to the heating plant. A new
appliance needs to complete the drying process of the paint. During the first heatings you
can notice the following situations:
- During the first ignitions the appliance may exhale bad smell. We suggest a good
aeration of the room till bad smells have been eliminated.
- The complete drying process will be obtained after some heating operations
The equipment is a wood stove with a functioning as Normative EN 13240. Thanks to
•
combustion chamber structure, the equipment has an high calorific efficiency. The cover
is complete in enamelled steel, in the visible models the fire and oven door has a
ceramic glass. The normal model has the fumes connection on right but it's available
also the left model.
COMBUSTIBLE LOADING
The appliance should be loaded manually during the functioning.
•
The loading of combustible should be done when the flame is minimum to avoid
•
combustion products or fumes outlet from the fire door.
To open the fire door, employ the fixture enclosed.
•
STARTING AND FUNCTIONNING
N.B. For starting never use : alcohol, fuel, or others liquid combustibles.
In case of starting during particular cooling days or in a condition of low pressure, it's
advisable to heat the flue before the starting, burning inside it some pieces of papers
For the combustible quantities please read the "Technical Data " ..
•
IGNITION
To arrange on foyer a cube-lighting or a small quantity of paper, around 0,5 kg of wood
•
in small pieces. Open entirely the prime and secondary air, light the paper and close the
foyer door.
When the appliance is completely lighted, add some larger wood pieces. Repeat this
•
operation till when the appliance has reached the " Hourly Charge " as indicated in the
technical details, than regulate the prime and secondary air as indicated in the chapter
Regulations
The equipment should be loaded when the flame i slow to avoid fumes or combustion
•
products escape.
During equipment functioning it's advisable to employ the ash-grater to clean the foyer
•
from ash and residuals.