At the Gun Cleaner
1. Remove the original suction hoses with their plugs from the Gun Cleaner's pumps (see Picture 1).
2. Place the Docking Unit in the Gun Cleaner so that the "DRESTER RDX" label is facing the front. Run the Docking Unit's
long hoses (black and white) through the left (or right) side-wall (see Picture 2).
3. Connect the Docking Unit's short hoses (black and white) to the Gun Cleaner's pumps (see Picture 4).
The black hose is connected to the lower pump.
The white hose is connected to the upper pump.
Now move the Docking Unit as far to the right as possible.
4. Cut off about 250 mm from the solvent return hose of the Gun Cleaner, then insert it in the Docking Unit (see Picture 3).
5. Insert the Gun Cleaner's suction hose (black, 6 mm in diameter) for manual cleaning with clean solvent (marked with a white
cable tie) through the centre plug of the Docking Unit (see Picture 5).
6. Insert the Gun Cleaner's suction hose (black, 6 mm in diameter) for manual cleaning with recirculating solvent (marked with a
black cable tie) in the front plug of the Docking Unit (see Picture 6).
7. Fit the maximum level indicator hose (transparent, 6 mm in diameter) onto the brass tube (see Picture 7).
8. Fit the two gas return hoses (transparent, 6 mm in diameter) onto the brass tubes (see Picture 8).
9. Connect the grounding cable (see Picture 9).
10. Disconnect the blue air line from the left side of the pressure regulator (see Picture 10).
11. Fit the control valve on the pressure regulator, and run the red hose through the left (or right) side-wall and place it with the
long black and white hoses (see Picture 11).
12. Connect the blue air line to the lower outlet fitting on the left side of the control valve. Connect the black hose for the Docking
Unit's pumps to the upper outlet fitting on the left side of the control valve (see Picture 12).
The installation at the Gun Cleaner is now completed.
At the Recycler
1. Picture 13 shows the enclosed valve components.
2. Fit the console with the control valve on the right side of the Recycler (see Picture 14).
3. Remove the plug from the solvent inlet and fit the 90º-coupling. If necessary, use the enclosed bushing (1/4 -3/8").
Then fit the brass connector (see Picture 15).
4. Connect the solvent hose (black with protective metal hose, see Picture 16).
5. Connect the distillate hose (see Picture 17).
6. Picture 18 shows the distillate container with level indicator.
7. Place the distillate container underneath the Recycler and insert the distillate hose (see Picture 19).
8. Connect the suction hose for clean solvent (white with protective metal hose, see Picture 20).
9. Trim the hoses from the Gun Cleaner to the correct length (see Picture 21).
10. Connect the hoses from the Gun Cleaner. Note the colour-coding: white for clean solvent, and black for
contaminated solvent (see Picture 22).
11. Connect the red air line (see Picture 23).
12. Connect clean, dry compressed air of 3–10 bar to the control valve inlet (see Picture 24).
13. Tie the hoses together using the supplied cable ties (see Picture 25).
The installation at the Recycler is now completed and the "DRESTER DYNAMIC TRIPLE 9000" is ready to be taken into use
(see Picture 26).
Warning:
Make sure that all parts of the system are grounded (machines and drums).
INSTALLATION
(see illustration enclosure 11144)
4