Proline Promag 53
Operation via
HART handheld
I
O
DXR 275*** * (Ex version,
I1
only for intrinsically safe
current circuits)
Promag
P = DN 15...300
W = DN 65...300
Promag
H = DN 2...25
➆
• Transmitter Promag 53 in: EEx de [ia] IIB/IIC T6 IP 6X
• Proline Ex d housing in: EEx d or EEx de
(The type of protection is the factor determining the choice of
cable entries and other line-entry elements)
• Sensor in EEx e [ia] IIC T1-T6 IP 6X:
Promag W DN 65...300
Promag P DN 15...300
Promag H DN 2...25
• For ambient and medium temperature as well as temperature classes and
maximum surface temperature: see Page 4.
• Note the maximum lengths for the cable between sensor and transmitter in
compliance with the regulations concerning Ex-group ratings:
IIC = max. 90 m / IIB = max. 200 m
Use only the cable sets supplied by E+H.
Endress+Hauser
Hazardous area
II2GD
Promag 53
P = DN 350... 600
W = DN 350...1200
➆
Promag
H = DN 40...100
Zone 1 / Zone 21
Hazardous area
Promag W DN 350...1200
Promag P DN 350...600
Promag H DN 40...100
r
Promag 53
Esc
-
+
E
➅
➆
➆
➄
➅
➆
II3GD
➄
Operation via
HART handheld
DXR 275 (only for
non-intrinsically safe
current circuits)
EX
Zone 2 / Zone 22
Transmitter terminal compartment
(EEx d or EEx e version) power supply/electric
circuit cable
Transmitter terminal compartment
(EEx e/EEx i version) sensor-cable connection
Sensor terminal compartment
(EEx e/EEx i version) sensor-cable connection
Safe area
I
O
EX
Safe area
3