WARNING!
This grill is designed for non-combustible enclosures only, and must be
!
installed and serviced by a quali ed installer to local codes.
WARNING!
As indicated on the rating plate, this gas grill is designed to operate with
supply pressures of 11" WC for Propane and 7" WC for Natural Gas. For installations where
the gas supply pressure exceeds these requirements, a regulator must be installed
upstream of the grill's components. If the gas supply pressure is lower than these require-
WARNING!
ments, the unit will be under- red and will not reach the maximum temperatures. Ensure
that the supply line size complies with local and/ or national installation codes.
!
1. DO NOT store or use products with flammable liquids or vapors in the
vicinity of the NEWAGE Grill Cabinet,NEWAGE Outdoor Kitchen cabinets or
any appliances.
2. DO NOT store a spare LP cylinder in or near the NEWAGE Grill Cabinet,
NEWAGE Outdoor Kitchen Cabinets, or any other appliances.
WARNING!
Care and Maintenance of your
Stainless Steel Grill
Perform Regular Maintenance
Wash regularly with clean fresh water, mild detergent and a micro fiber cloth. After washing rinse in clean
water and wipe the surface dry with your cloth remembering to go with the grain on brushed stainless steel.
Generally you should wash your stainless steel every three months. Coastal areas or next to a chlorine pool
more frequently every 2 weeks. Do not use abrasive cleaners or a scouring pad of any type as they will cause
excessive wear and dull the finish.Stainless steel finishes in coastal environments may show tea staining if
not washed regularly. For better protection use a thin coating of protection on the surface.
List of common conditions that cause corrosion or discoloration of
stainless steel and should be avoided:
1. Chloride containing cleansers – this includes bleach and any cleaners containing bleach
2. Muriatic acid (hydrochloric acid) – commonly used to clean up after tile/concrete installation
3. Concentrated soap residue – chemical additives will cause discoloration and some dried soaps
actually look like rust
4. Water with high iron content – can leave a rusty residue, especially if allowed to drip continuously
5. Contact with iron materials – including steel wool, iron residue/dust from installation or cleaning of other
steel products
6. Don't' allow trapped moisture between the product and cover – rubber mats, metal cans or cleaning
products trap moisture - allow cabinets to completely dry before covering.
7. Salts – contain chlorides
8. Extreme Heat by Flame
9. Do not permit citrus or tomato juice to remain on stainless steel surfaces.
10. No abrasive cleaners, steel wool pads, or abrasive cloths as they will scratch the finish.
18
www.newageproducts.com
OXIDIZATION Removal
If you have oxidation there are a few steps to take to bring your stainless steel cabinets back to "as new"
condition. Apply clean water with a cleaning sponge and rub gently in the direction of the grain. If the
mark won't shift, it may be necessary to use a stainless steel cleaner, in which case apply the cleaner and
rub gently. After cleaning it is important to rinse the stainless steel with clean fresh water and buff with
a soft cloth. Remember to always rub with the grain, NEVER across as you will ruin the finish, and the
stainless can lose its shine.
Gas Connections
Never connect a gas line directly to the grill. A pressure regulator must be installed
on all gas equipment. All local codes require a pressure regulator and NewAge
supplies the correct regulator with your grill. Removing or failing to install the
pressure regulator can result in fire, and serious personal injury and will void the
warranty. This grill is designed for non-combustible enclosures only, and must be
!
installed and serviced by a qualified installer to local codes.
As indicated on the rating plate, this gas grill is designed to operate with gas
supply pressures of 11" WC for Propane and 7" WC for Natural Gas. For installations
WARNING
where the gas supply pressure exceeds these requirements, a regulator must be
installed upstream of the grills components. If the gas supply pressure is lower than
these requirements, the unit will be under-fired and will not reach the maximum
temperatures. Ensure that the supply line size complies with local and/or national
installation codes.
The grill is factory set to use natural gas (NAT) To use Propane, a conversion kit must be installed. It is critical
that the gas you use matches that which the grill was set up for. You can verify that by checking the rating
plate.
CAUTION:
OUTDOOR COOKING APPLIANCE- FOR OUTDOOR USE ONLY. IF STORED INDOORS,
USE ONLY THE GAS PRESSURE REGULATOR (LP ONLY)
CLASS NO / CATÉGORIE #: 2711 04
ORIFICE SIZES/
PROPANE
- 65901
GRANDEUR DES ORIFICS
DETACH AND STORE GAS CYLINDER OUTSIDE. DO NOT USE THIS APPLIANCE
PROVIDED WITH THIS APPLIANCE. THIS REGULATOR IS SET FOR AN OUTLET
MODEL/ MODÈLE 40"
UNDER OR CLOSE TO UNPROTECTED OVERHEAD COMBUSTABLE SURFACES.
PRESSURE OF 11 INCHES OF WATER COLUMN (2.74 kPa). THE APPLIANCE CAN
MAIN BURNER/
1.18MM
BRÛLEUR PRINCIPAL
SEE INSTRUCTIONS FOR CLEARANCES.
ONLY FOR INSTALLATION IN A BUILT-IN
BE USED WITH LP GAS AND NATURAL GAS. THIS APPLIANCE IS ADJUSTED AND
3 X 16,000 BTU/ U MAIN BURNERS / BRÛLEUR PRINCIPAL
ENCLOSURE CONSTRUCTED OF NON-COMBUSTIONABLE MATERIALS.
SHIPPED FOR USE WITH NATURAL GAS. TO CONVERT TO LP GAS, USE ONLY A
1 X 12,000 BTU/ IR REAR BURNER / BRÛLEUR ARRIÈRE
BACK BURNER/
1.03MM
BRÛLEUR A L'ARRIÈRE
WARNING:
SUPPLIED LP GAS CONVERSION KIT. REFER TO INSTRUCTION MANUAL FOR HELP
GAS SUPPLY MUST BE TURNED OFF AT SOURCE/ CYLINDER
1 X 15,000 BTU/ IR SEAR BURNER / BRÛLEUR SAISIR
SEAR STATION BURNER/
1.18MM
WHEN APPLIANCE NOT IN USE. DO NOT STORE A SPARE LP GAS CYLINDER UNDER
MINIMUM CLEARANCE TO ADJACENT COMBUSTABLES:
INFRAROUGE À HAUTE TEMPÉRATURE
BRÛLEUR INFRAROUGE
OR NEAR THIS APPLIANCE. NEVER FILL THE CYLINDER BEYOND 80% FULL.
APPAREIL DE CUISINE DE PLEIN AIR- UTILISE À L'EXTÉRIEUR SEULEMENT.SI
DÉGAGEMENT MINIMUM AUX COMBUSTIBLES ADJACENTS
11" LPG / 7" NG
IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE CAUSING DEATH
MANIFOLD PRESSURE INCHES OF WATER COLUMN
MAINTENU À L'INTÉRIEUR, DÉCHARGEZ ET CONSERVEZ LE BONBONNE AU GAZ
INCHES FROM SIDES
10
POUCES DES CÔTÉS
PRESSION AU COLLECTEUR (DE POUCES COLONNE D'EAU)
OR SERIOUS INJURY MAY OCCUR.
À L'EXTÉRIEUR. N'UTILISEZ PAS CET APPAREIL SOUS OU À PROXIMITÉ D'UNE
INCHES FROM REAR
18
POUCES DE L'ARRIÈRE
11 po GPL/ 7 po GN
CONSTRUCTION COMBUSTIBLE.
Rating Plate - Lists serial numbers, model numbers,
and gas type
Water Column Requirements
The rating plate is located in one or more of the following places:
•
On the back of BBQ
Ensure that the gas supplied meets with the minimum pressure requirements. Do not operate the grill on
any gas other than that for which the grill has been set.
Both the regulator and the manifold orifices have been tuned for the type of gas specified on the rating
plate. Converting to a different type of gas requires a conversion kit, supplied from NewAge and must be
installed by a qualified technician.
All installation and all installation parts must conform to local codes with the National Electrical Code,
ANS Z223.1/ NFPA 54 latest edition and the National Fuel Gas Code, ANS Z223.1/NFPA 54 in the U.S. and
CSA-B149.1/.2 in Canada. Canadian installations must conform to CSA-B149.1/.2 natural gas/propane
installation code. (Canada)
www.newageproducts.com
ATTENTION:
GRILL ELECTRICAL REQUIREMENTS:
NATURAL GAS
ONLY FOR INSTALLATION IN A BUILT-IN ENCLOSURE
L'ALIMENTATION DE GAZ DOIT TOUJOURS ÊTRE FERMEZ À LA SOURCE /
GAZ NATURAL
CONSTRUCTED OF NON-COMBUSTIONABLE MATERIALS OR
BONBONNE QUAND L'APPAREIL N'EST PAS UTILISÉ
INPUT- 110 VAC 60 Hz 0.25A
111 CREDITVIEW ROAD, 2nd FLOOR
1.61MM
NEWAGE CSA APPROVED GRILL CABINETS. SEE MODELS.
NE GARDER PAS UN BONBONNE AU GAZ LP EN RÉSERVE DESOUS OU À PROXIMITÉ DE CET
ROTISSERIE ELECTRICAL REQUIREMENTS:
UNIQUEMENT POUR L'INSTALLATION DANS UN BOÎTIER
APPAREIL.
INPUT- 110 VAC 60 Hz 0.04A
1.39MM
INTÉGRÉ CONSTRUIT DE MATÉRIAUX NON COMBUSTIBLES
OU POUR APPAREIL DE GRILLE ET D'ARMOIRES NEWAGE,
SI L'INFORMATION PRÉCÉDENTE N'EST PAS SUIVIE EXACTEMENT, UN INCENDIE PROVOQUANT
MFG DATE DE FABRICATION :
1.53MM
APPROUVÉ CSA.
UNE MORT OU DES BLESSURES GRAVES PEUVENT PRODUIRE.
AVERTISSEMENT
NO01-MAR2018A
UTILISEZ UNIQUEMENT LE RÉGULATEUR DE PRESSION DE GAZ
:
EQUIPPED FOR USE WITH
(LP SEULEMENT) QUI EST FOURNI AVEC CET APPAREIL.
Class IIIA-2
X
CE RÉGULATEUR EST RÉGLÉ POUR UNE PRESSION DE PRISE DE 11 POUCES DE COLONNE
NATURAL GAS / GAZ
LPG
D'EAU(0.39 PSI)
Fuel
NATURAL GAS
7 in wc (NG)
LP
11 in wc (LPG)
L4L-9T1
CAN/CSA- 1.6-2015
ANS Z21.58-2015
OUTDOOR COOKING
GAS APPLIANCE
WC Min Under
Full Load
19