General Instructions

Installation:
1. Turn off water supply and drain lines. Drill a hole approximately 7/8" (22mm)
diameter in sink or countertop where you are installing no.1.
2. Loosen no.6 with a wrench and
remove no.6, no.5, no.4, and no.3 from
threaded end of no.2.
3. Place no.2 through hole in sink or
countertop. Reinstall no.3, no.4, no.5
and no.6 onto no.2. Tighten no.5 against
bottom of sink or countertop
with a wrench.
4. Apply teflon tape or pipe joint
compound to threaded end of no.2,
connect cold water supply inlet
to no.2. Or use no.6 if compression
fitting is used.
5. Turn on water supply
and check for leaks.
Adjustment:
Volume control
6. To adjust height of water flow,
rotate no.7 on bottom side of no.10
using a 3/32" hex wrench (do not
remove).
7. To raise height of water, turn no.7
counterclockwise. To lower flow of
water, turn no.7 clockwise.
Note: The valve index is vandal-resistant. A #8 spanner driver is required to
service the valve assembly (available as T&S part no.BL-5707-05).