Information SILVER+ / GOLD+ Decoder
Set bit 8(7) in CV51 to activate the constant braking distance with speed step 0.
You can find detailed information on setting the braking distance in the "Manual Plus Decoders" that
you
can
download
from
the
Lenz
Elektronik
GmbH
website
www.lenz-
elektronik.de/pdf/download.php
Important advice:
The length of the covered braking distance is set in CV52. The braking distance differs depending
on the value set in this CV.
If you want to use the constant braking distance with both speed step 0 and ABC, set both bits in
CV51.
While the shunting speed is switched off (default setting F3), the constant braking distance is
disabled and the delay from CV4 becomes effective.
The constant braking distance is also disabled if the delays set in the decoder are disabled by
means of the corresponding function.
The two latter features can also be used sensibly if you wish to interrupt a current braking process
prematurely.
The constant braking distance does not work if the layout is operated in analogue DC mode.
6.6 Shunting speed
The shunting speed halves the speed. This facilitates particularly sensitive control of the shunting
process. Use function 3 (ex-works setting, can be altered in CV59) to enable and disable the
shunting speed. If the shunting speed is enabled, the constant braking distance is disabled. The
shunting speed is enabled as long as the function is active.