operation. If this is the case, activate your EMF switch by setting Bit 6 in CV 50. The locomotive will
then reach a higher maximum speed while the minimum speed is also slightly increased.
6.3 Running notches (Speed steps)
The decoder can be operated in the 14/27 or the 28/128 running-notches mode. This setting is
made in CV29.
6.4 Disabling of delay
Use function 4 (ex-works setting, can be altered in CV60) to disable the starting and braking delay
as well as the constant braking distance during operation. The delays are disabled as long as the
function is active.
6.5 Constant braking distance
6.5.1
Constant braking distance with ABC
Functioning: If the decoder recognises the command "Stop" while in ABC mode, the locomotive will
stop after the set braking distance has been covered. This braking distance is independent of the
speed of the locomotive.
You can activate the constant braking distance with ABC by setting bit 1(0) in CV51.
6.5.2
Constant braking distance with speed step 0
Functioning: During the transition from any speed step to speed step 0 (e.g. by turning the knob of
the manual control to the very left) the locomotive or train covers a settable, defined braking
distance. This distance is independent of the speed of the locomotive. The constant braking
distance is only effective if the speed step is set to 0. If the speed step is decreased from e.g. 28 to
10, the speed-dependent delay from CV3 becomes effective.