Filter Replacement; Troubleshooting - MW TOOLS LA2801 Mode D'emploi

Aspirateur de fumée de soudage
Masquer les pouces Voir aussi pour LA2801:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

M1.1.LA2801.NLFREN 14082018
EN

6.1 Filter replacement

Removing the filters may expose you to hazardous contaminants. Take all necessary precautions including protective
clothing such as eye protection and gloves.
Follow all local safety and environmental codes in disposal of the accumulated particulate.
Sparkproof filter: 9 - 18 months
PFTE filter: 6 - 12 months
Charcoal filter: 9 - 18 months

8 Troubleshooting

Problem
Extraction arm is not holding position
System will not turn on
Blower will not get up to speed or stay
running
Fume bypass or leaking is present
Sparkproof filter
Charcoal filter
Sparkproof filter
Possible causes
Tension on joints has loosen
Support spring is damaged or worn
Power connection
Supplementary protector tripped
Power supply
Motor or blower damage
Filter damage
Filter is not installed correctly
Solutions
Adjust the arm joints
Inspect gas spring and repair, replace
as necessary
Verify that the unit is connected to the
proper power supply
Reset the supplementary protector
Check the supply fuse or breaker and
verify it is properly rated for use
Inspect the blower wheel and motor for
damage or excessive vibration
Inspect filter for any damage to the
media, replace if needed
Verify that the filter is properly seated
and access hatch is securely fastened
13