INSTALLATION INSTRUCTIONS

Location
The tank must sit level or slope slightly towards the drain valve to allow the tank to drain properly.
It is extremely important to install the compressor in a clean, well ventilated area where the surrounding air
temperature will not be more than 100°F. A minimum clearance of 4 inches between the compressor and a wall is
required because objects could obstruct air flow.

Electrical Installation

electrical codes.

Grounding Instructions

1. This product is for use on a nominal 120 volt circuit and
has a grounding plug that looks like the plug illustrated in
Figure 2. Make sure the product is connected to an outlet
having the same configuration as the plug. This product
must be grounded. In the event of an electrical short circuit,
grounding reduces risk of electrical shock by providing an
escape wire for electric current. This product is equipped
with a cord having a grounding wire with an appropriate
grounding plug. Cord must be plugged into an outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.
2. If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade
terminal. The wire with insulation having an external surface that is green (with or without yellow stripes) is
the grounding wire.
3. Check with a qualified electrician or serviceman if grounding instructions are not completely understood, or if
in doubt as to whether product is properly grounded. Do not modify plug provided; if it will not fit outlet, have
proper outlet installed by a qualified electrician.
Wiring
1. Local electrical wiring codes differ from area to area. Source wiring, plug and protector must be rated for
at least the amperage and voltage indicated on motor nameplate, and meet all electrical codes for this
minimum.
2. Use a slow blow fuse or a circuit breaker.
Do not locate the compressor air inlet near steam, paint spray, sandblast areas or
any other source of contamination.
All wiring and electrical connections should be performed by a qualified
electrician. Installation must be in accordance with local codes and national
Improper use of grounding plug can result in a possible risk of electrical shock!
Do not use a grounding adapter with this product!
Never connect green (or green and yellow) wire to a live terminal.
Grounded
Outlet
Grounded
Pin
Figure 2
5