Summary List Of Rdm Pids For Lwcyc-00B Normal Responses - Leviton LWCYC-00B Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION
(continued)

SUMMARY LIST OF RDM PIDS FOR LWCYC-00B NORMAL RESPONSES

RDM PIDs normally responded by LWCYC-00B are as shown in the following table:
1
2
3
4
5
6
7
DEVICE_MODEL_DESCRIPTION
8
9
10
11
12
13
DMX_PERSONALITY_DESCRIPTION
14
15
16
17
If RDM console sends any RDM PID excluded in the table, LWCYC-00B will respond in the format of NR_UNKNOWN_PID.
After RDM console sends SET_IDENTIFY_DEVICE_ON instruction to LWCYC-00B, the LED display will display IDEN
(regardless of previous turn-off of the display). This display content will not be changed and display will not be turned OFF.
During this period, even if the function setting knob is operated, the display content will remain unchanged. The setting
change function will be temporarily disabled, and only after the SET_IDENTIFY_DEVICE_OFF instruction sent by RDM
console is received, can this state be released.
RDM PID
DISC_UNIQUE_BRANCH
DISC_MUTE
DISC_UNMUTE
SUPPORTED_PARAMETERS
DEVICE_INFO
PRODUCT_DETAIL_ID_LIST
MANUFACTURER_LABEL
DEVICE_LABEL
FACTORY_DEFAULTS
SOFTWARE_VERSION_LABEL
DMX_PERSONALITY
DMX_START_ADDRESS
SENSOR_DEFINITION
SENSOR_VALUE
IDENTIFY_DEVICE
6
GET
SET

Publicité

Table des Matières
loading

Table des Matières