With cleaning and maintenance on the machine,
Filter change:
the power cable should be disconnected from the
supply.
The fi ne fi lter should be changed at least once per
year. If the machine is used with a microfi lter/HEPA
fi lter, this should be changed every 300 running
hours. Use breathing protection when changing the
fi lter. Care must be taken during the fi lter change
not to expose unprotected persons to harmful dust.
Used fi lters should be sealed in a plastic sack and
disposed properly.
When changing the fi lters, check the gasket. An un-
sealed gasket can cause discharge of whealty dust.
Check regularly that the electrical cable is not da-
maged.
The DC 2800a should be performance tested at least
once per year because it may be used with hazardus
materials. Worn parts must be replaced. Dustcontrol
is not responsible for machines that are equipped with
other than original spare parts.
The fan is maintenance free.
Filterchange HEPA fi lter:
1.
2.
3.
Part No. 42027
4.
5.
6.
7.
DC 2800a - 10
Art nr 9454