OC 0350
INDUCTION DENT REMOVAL
2. Transmission table of analog control
Power
(%)
10
20
30
40
50
INTERNAL CONNECTION OF THE REMOTE CONTROL
WARNING!!!!!!!!
The remote control circuits are not galvanically isolated from the secondary control circuits
of the OC 0350, therefore it is necessary to use optoelectronics, relays or galvanically
isolated transducers according to IEC 60071-1 and IEC 60664-1 to connect a parent system!
The supplier reserves the right to terminate the warranty period in the event of damage
resulting from incorrect or incorrect connection of the remote connection circuits.
INV intervals
INC intervals
(V)
(mA)
0-1
0-5,6
1-2
5,6-7,2
2-3
7,2-8,8
3-4
8,8-10,4
4-5
10,4-12
Power
INV intervals
(%)
(V)
60
5-6
70
6-7
80
7-8
90
8-9
100
9-10
INV intervals
(mA)
12-13,6
13,6-15,2
15,2-16,8
16,8-18,4
18,4-20