OC 0350
INDUCTION DENT REMOVAL
1. Operating cycle
However, this is determined by the operating conditions. When heating in the immediate
vicinity of the material, it is impossible to prevent heat transfer to the heating inductor.
For this reason, the heating inductor is protected against overheating by measuring its
temperature and automatically interrupting the power transfer in the event of overheating
of the instrument or inductor.
For heating inductances, their maximum charge cycle is designed for refrigerated surfaces
during operation. In the actual use of the device can take the value of the duty cycle only
for information purposes.
CONTROL PANELS
1. Main switch
The main switch for the induction dent removal unit is located on the rear face of the unit.
2. Description of the front control panel
N°
1
2
3
4
5
Descriptions
Heating indicator
Micro-USB socket
Display
Power indicator
Timer indicator
N°
Descriptions
6
External connection indicator
7
Encoder
8
Output socket
Remote control connection
9
socket