Troubleshooting - Zephyr Tempest I AK7000BS Guide D'utilisation, D'entretien Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING PROCEDURES FOR TEMPEST I
Issue
Cause
After installation,
1. The power source is not turned ON.
the unit doesn't
is not connecting properly.
3. The switch board and control board wirings are
disconnected.
4. The wires on control board are loose.
5. The switch board or control board is defective.
1. The blower wire is not connected.
blower is not
turning.
3. The blower is defective, possible seized.
4. The thermally protected system detects if the
blower is too hot to operate and shuts the blower
down.
5. Damaged capacitor.
The unit is
1. The blower is not secure in place.
vibrating.
2. Damaged blower wheel.
3. The hood is not secured in place.
The blower is
1. The light bulb plug is disconnected.
2. Defective halogen bulb.
lights are not.
3. The light bulb is loose.
The speed levels
1. Using the wrong size of ducting.
of the blower
sound the same.
The hood is
1. The hood might be hanging to high from the
not venting out
properly.
2. The wind from the opened windows or opened
ventilation of the hood.
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.
5. Using the wrong size of ducting.
vibrating.
RF Remote
1. Battery is dead.
control does not
2. Poor communication with the hood.
3. RF remote lost communication with the hood.
The blower turns
1. The clean air function has been enabled turning
on by itself.
the blower on every 4 hours.
What to do
power is ON.
connected properly.
board and control board are connected
properly.
connected properly.
5. Change the switch board or control board.
molex connector.
inside plug to see if pin is pushed inside the
plug too far. Reseat pin if needed.
3. Change the blower.
4. The blower will function properly after the
thermally protected system cool down.
5. Change the capacitor.
1. Tighten the blower in place.
2. Change the blower.
1. Connect the light bulb plug.
2. Change the halogen bulb.
3. Tighten the light bulb.
1. Change the ducting to at least 8" round or
3-1/4"x10" rectangular for single blower or 10"
round for dual blower.
the bottom of the hood within 26" and 36"
range.
2. Close all the windows and doors to eliminate
duct opening.
5. Change the ducting to correct size.
2. Change the spring clip.
1. Replace the battery with type A23 12v.
2. Remote must be within 15 feet of the hood.
3. Reset the hood and remote by switching the
Perform remote synchronization process on
page 18.
1. Disable the clean air function by following the
steps on page 17.
21