www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
AK7748AS - 299 Watts, 4.2 Amps Power consumption shown above is the default power specs. Hoods with Zephyr’s proprietary Airflow Control Technology (ACT) enabled will consume less power. See wiring diagram at the end of this manual for more information.
Page 7
Equivalent number Duct pieces Equivalent number Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
Page 8
www.zephyronline.com ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size. If turns or transitions are required; install as far away from hood duct output and as far apart, between the two as possible. Minimum mount height between range top to hood x .
Page 9
WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use rigid metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certified Aluminum Tape or Duct Tape. Some Ducting Options Roof Pitch w/ Flashing &...
Page 10
www.zephyronline.com ” Standard Min. - 33” Max. - 50“ ” (36”, 42“) 15/16 Z1C-0077 (36”, 42“) (48”) 5/8” Z1C-0177 (48”) Min. - 49” Max. - 78” ” (36”) 15/16 ” (42”) 15/16” (48”) 15/16” SIDE FRONT ” (36”, 42“) (48”) 15/16”...
Page 11
CAUTION: At least two installers are required due to the weight and size of the hood. FRONT Ceiling Joists Wood Blocking Cut-Out Shaded Area XP022220 Top Support Frame FIG. B Support Frame Arm Bottom Support Frame Mounting Screws (pre-installed) Hood Body FIG.
Page 12
www.zephyronline.com Duct Cover Standard Frame Top Support Frame Assembly Instructions FIG. F FIG. D Bottom Support Frame (secures to top of blower housing) back Key Holes front - facing controls FIG. C FIG. E 3. Attach square support bracket inside the support frame assembly. The placement of the square support bracket should preferably be aligned in the middle where the top and bottom frame intersect (FIG.
Top Support Frame Top Duct Covers Cable Lock A cable locking connector (not supplied) might be required by local codes. Check with local requirements and codes, purchase and install appropriate connector if necessary. Bottom Duct Covers Cable Lock Bottom Support Frame FIG.
Page 14
www.zephyronline.com This range hood is equipped standard with a single blower vertical duct option. To convert from single blower vertical ducting to dual blower vertical ducting please following the instructions below. 1. Disconnect blower plug and white and black 2. Remove (4) screws from interior of hood body power cables.
Page 15
Power / Delay Off Display Adjust 6 Speed Levels Lights On/Dim/Off 1. Power / Delay Off Power Button Function On/Off button will turn power on and off for entire hood (fan and lights). The hood will remember the last speed and light level it was turned off at.
Page 16
The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. 1. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote.
Directional Lighting The light bulbs can be tilted forwards and backwards to better direct light over your cooking surface. FIG. J. Replacement bulbs are available to purchase directly from Zephyr. Purchase online at http://store.zephyronline.com or call us at 1.888.880.8368 FIG. I...
www.zephyronline.com TROUBLESHOOTING PROCEDURES Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
Some local codes limit the maximum amount of CFM a range hood can move. ACT™ allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT™ enables the installer to easily set the maximum blower speed to one of two most commonly specified CFM levels;...
Page 20
www.zephyronline.com ACT 590 CFM - Fan Max. 175W @ 2.6A ACT 390 CFM - Fan Max. 94W @ 1.4A ACT 290 CFM - Fan Max. 63W @ 0.9A...
Page 21
DESCRIPTION PART# Replacement Parts LED Light Bulb MR16 (GU10) 6W (each) Z0B0040 Baffle Filter (each) 50210036 Optional Accessories Duct Cover Extension (36”, 42”) Z1C-0077 Duct Cover Extension (48”) Z1C-0177 Dual Internal Blower PBD-1300A Make-Up Air Kit (Single Blower) MUA008A Make-Up Air Kit (Dual Blower) MUA010A To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
Page 22
Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:...
PRODUCT REGISTRATION Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes.
Page 26
MISE EN GARDE DE SÉCURITÉ ... 2-3 ..............LISTE DU MATÉRIEL ......................INSTALLATION Feuille de calcul pour le conduit .................. Espace libre et hauteur de montage ................. Options d’installation pour le conduit ................ Spécifications ........................Installation de la hotte... 9-11 ....................
Page 27
www.zephyronline.com LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a.
ATTENTION POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage.
www.zephyronline.com www.zephyronline.com www.zephyronline.com www.zephyronline.com MODÈLES: AK7736AS, AK7742AS, AK7748AS PIÈCES FOURNIES 1 - Hotte 4 - Couvre-conduits, 2 supérieurs et 2 inférieurs 2 - Cadres de soutien, 1 supérieur et 1 inférieur 2 - Équerres de fixation 1 - Cadre de support central 4 - Filtres déflecteurs, AK7736AS &...
Page 30
Longueur x Pièces de conduit Longueur x Pièces de conduit T otal T otal Nombre utilisé Nombre utilisé 3- 1/ 4” x 10” 1 pi 6” circ. à 5 pi rect., droit rect. de 3-1/4" x 10" 6”, 7”, 8”, 10” 1 pi 6”...
www.zephyronline.com adaptateurs sont nécessaires, installez-les le plus loin possible de l’ouverture et le plus éloigné possible l’un de l’autre. La hauteur de montage de la surface de la cuisinière au bas de la hotte ne devrait pas être inférieure à 24”. La hauteur de montage maximale ne devrait pas outrepasser 36”.
AVERTISSEMENT DE RISQUE D’INCENDIE N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison. N’utilisez que des conduits en métal pour cloison simple. Fixez toutes les pièces du conduit avec des vis à...
www.zephyronline.com ” Standard Min. - 33” Max. - 50“ ” (36”, 42“) 15/16 Z1C-0077 (36”, 42“) (48”) 5/8” Z1C-0177 (48”) Min. - 49” Max. - 78” ” (36”) 15/16 ” (42”) 15/16” (48”) 15/16” DEVANT CÔTÉ ” (36”, 42“) (48”) 15/16”...
Page 34
ATTENTION : Compte tenu du poids et des dimensions de la hotte, au moins deux installateurs sont nécessaires. DEVANT Solives de plafond Bloc de bois Zone de découpage ombragée XP022220 Cadre de fixation supérieur FIG. B Bras du cadre de fixation Cadre de fixation inférieur Vis de montage...
www.zephyronline.com Couvercle des conduits Instructions Cadre de support supérieur d'assemblage du cadre standard FIG. F FIG. D Cadre de fixation inférieur (est fixé à la partie supérieure du boîtier du ventilateur) Encoches en trou Devant – commandes à l’avant FIG. C FIG.
Cadre de fixation supérieur Pièces de recouvrement Raccord de câble supérieures Un raccord de câble (non inclus) pourrait également être exigé par les normes et réglementations locales. Informez-vous des exigences et des normes locales. Achetez et installez le connecteur approprié si nécessaire.
Page 37
www.zephyronline.com Cette hotte standard est munie d’une entrée pour conduit vertical avec un ventilateur simple. Pour la convertir d’un conduit vertical à ventilateur simple à un conduit vertical à ventilateur double, veuillez suivre les instructions ci-dessous. 2. Enlevez les quatre (4) vis de l’intérieur de la 1.
Page 38
Mise en marche/Arrêt à retardement Tableau d’affichage Sélection de la vitesse Lumières - Allumer/Veilleuse/Éteindre 1. Mise en marche/Arrêt à retardement Fonction de mise en marche La touche On/Off permet d’allumer et d’éteindre toutes les fonctions de la hotte (ventilateur et lumières). Lorsqu’elle est éteinte, la hotte garde en mémoire la dernière vitesse du ventilateur et le dernier réglage d’intensité...
La commande à distance radioélectrique est munie d’un aimant pour un entreposage facile. La commande peut être mise sur n’importe quelle surface magnétique, comme un réfrigérateur ou le support à commande Zephyr (FIG. 1). Le support à commande peut s’installer à une prise électrique standard pour un rechargement facile.
Les ampoules peuvent être inclinées vers l’avant et vers l’arrière pour mieux diriger la lumière sur votre surface de cuisson (FIG. J). Les ampoules de rechange sont disponibles à l’achat directement auprès de Zephyr. Achetez en ligne à http://store. zephyronline.com ou appelez-nous au 1.888.880.8368 FIG.
www.zephyronline.com Procédures de Dépannage Problème Cause Solution Après 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur l’installation, et de l’appareil est allumée l’appareil ne 2. La ligne électrique et le raccord de câble ne sont 2.
Page 42
/min qu’une hotte peut extraire. La ACT™ permet de contrôler la quantité maximale de pi /min qu’évacuent un éventail de hottes Zephyr, éliminant la nécessité d’acheter un dispositif d’air d’appoint dispendieux. La ACT™ permet à l’installateur d’ajuster facilement la vitesse maximale du ventilateur à...
Zephyr Ventilation, LLC (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...
ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente.