The SINGLE SEQUENTIAL ACTUATION
MECHANISM may also reduce the speed
of operation compared to the CONTACT
ACTUATION MECHANISM. The SINGLE
SEQUENTIAL ACTUATION MECHANISM is
recommended to inexperienced users.
NOTE
● If all warnings and instructions are
followed, safe operation is possible with
all two systems: SINGLE SEQUENTIAL
ACTUATION MECHANISM and CONTACT
ACTUATION MECHANISM.
● Always handle nails and package carefully.
If nails are dropped, collating bond may be
broken, which will cause mis-feeding and
jamming.
● After nailing:
1) disconnect air hose from the Nailer;
2) remove all nails from the Nailer;
3) supply 5 – 10 drops of Hitachi
pneumatic tool lubricant into the air
plug on the Nailer; and
4) open the petcock on the air compressor
tank to drain any moisture.

ADJUSTING THE NAILING DEPTH

● When adjusting the Adjuster, be
sure to remove your fi nger from the
trigger and disconnect the air hose
from the nailer.
To assure that each nail penetrates to the
same depth, be sure that:
1) the air pressure to the Nailer remains
constant (regulator is installed and working
properly), and
2) the Nailer is always held fi rmly against the
workpiece.
If nails are driven too deep or shallow into the
workpiece, adjust the nailing in the following
order.
1 DISCONNECT AIR HOSE FROM NAILER.
2 If nails are driven too deep, turn the
adjuster to the shallow side.
Adjustments are in half-turn increments.
18
WARNING
Adjuster
If nails are driven too shallow, turn the adjuster
to the deep side.
3 Stop turning the adjuster when a suitable
position is reached for a nailing test.
4 Connect the air hose.
ALWAYS WEAR SAFETY GLASSES.
Perform a nailing test.
5 DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.
2
Turn Adjuster
Too Deep
2
Too Shallow
Turn Adjuster

USING THE BLOW NOZZLE

● Be sure to release your fi nger from
the trigger before using the blow
nozzle.
● Do not point the air outlet at a
person.
● Do not use the blow nozzle with the
push lever left fi t.
15 Disconnect air
hose
Flush
Flush
WARNING