Faults
9. 1
Behaviour of the F 1200+ drive in the event of faults
Problem
The window blocks during
closing from the tilt position.
LED status display flashes
yellow.
The window is not locked
following closing from the
turn position. LED status
display flashes yellow.
The control panel is not illu-
minated when approached.
The control panel does not
react when a key is pressed.
No display appears when
a key is pressed.
The LED status display does
not light up.
9.2
Eliminating blockages
CAUTION!
Injuries caused by impact, crushing and pinching!
Make sure there are no body parts (hands, fingers) in the closing area of the leaf.
X
Cause
Remedy
There is an obstacle (e.g.
X
forehand, object) in the
closing path of the leaf.
The window is not closed
properly.
The proximity sensor is
The keys can still be pressed on the control panel.
not reacting.
X
The activated keys light up.
The drive is faulty.
X
X
X
X
Use of the window unit is still possible.
X
X
Eliminate the blockage (see chapter 9.2 "Eliminating
blockages").
Touch any key on the control panel.
Contact the operator or GEZE Service.
Have the control panel checked by an authorised
service technician.
Contact the operator or GEZE Service.
Have the control panel checked by an authorised
service technician.
Contact the operator or GEZE Service.
Have the LED status display checked by an authorised
service technician.