4.Initial operation, set-up and electrical
connection
The filter cartridge pre-filter is a pre-filtering module connected between the suction point
●
and a fume extraction device.
The device is supplied ready to plug in.
●
Install the collection element, extraction pipe and, if need be, other accessories.
●
Connect the downstream-connected fume extraction device with the mains supply.
●
Turn on the power switch of the downstream-connected fume extraction system.
●
Optional extensions of the filter cartridge pre-filter
1. Differential pressure switch Art. No. 14177 :
monitors the filter's differential pressure (degree of filter saturation) and closes a relay
contact at reach of the preset value (500 – 2500Pa).
Factory-provided setting: 1500Pa
2. Precoating element:
A precoating element provides for the possibility of extracting tacky substances.
pre-treatment (Precoating) of the filter cartridges with Precofix 200, an interlayer is
By
created between the filter and the extracted medium, forming a filter cake that falls off
the filter when it is cleaned.
The filter cartridges have to be precoated after every cleaning action.
FPV 100 V4.30
Before performing maintenance activities at the FPV device, the
downstream-connected fume extraction device always has to be switched
off first (switch off and disconnect from the mains)
-16-
Technische Änderungen vorbehalten
Technical changes reserved
Sous réserve de modifications techniques