Door Access - Vestibule - MyQ LiftMaster CAPAC Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INTRODUCTION

Door Access - Vestibule

DO NOT INSTALL THE SYSTEM IN THE FAIL SECURE MODE
INTRODUCTION
UNLESS PERMITTED BY THE LOCAL AUTHORITY HAVING
JURISDICTION. Doing so may cause interference with the
operation of panic hardware.
INTRODUCTION
NOTE: For UL
installations, only UL
294 Listed electric
door strikes or UL
294 Listed maglocks
may be connected to
relay output 1 or 2.
PRIMARY RELAY
DOOR STRIKE
Use 18-22 AWG
For DC Power:
Install a 1N4005
diode or equivalent
Use 18-22 AWG
For DC Power:
Install a 1N4005
diode or equivalent
PRE-INSTALL
PRE-INSTALL
PRE-INSTALL
OUTPUT
1
OUTPUT
GATE
SDA SCL
NO COM NC
NO COM NC
For AC Power:
Install a Siemens
S10K30MOV
(Metal Oxide Varistor)
(provided) or equivalent
Power for Door Strike
(Not Provided)
COMMON
+
NORMALLY OPEN
OR
MAGLOCK
For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) (provided)
or equivalent
NORMALLY CLOSED
COMMON
+
Power for Maglock
(Not Provided)
DO NOT use the power
supply for the controller
INSTALL
Not responsible for conflicts between the information listed in
INSTALL
the wiring diagram and the requirements of your local building
codes. The information is for suggested use ONLY. Check your
local codes BEFORE installation.
INSTALL
WIEGAND
INPUT
2
1
2
WIEGAND
D1 COM D0
D1 COM D0
1 GND 2
AUXILIARY RELAY
Auxiliary Relay follows the same wiring schedule
as the Primary Relay.
13
NETWORK
ACCESS CONTROL
NETWORK
ACCESS CONTROL
NETWORK
ACCESS CONTROL
INPUT
POWER
GND 12V-24V
POWER
ETHERNET
SUPERVISED (DOOR STATUS) 1
DOOR SENSOR
(NON-SUPERVISED)
EOL (End of Line) Resistor
(1k ohm)
SUPERVISED (DOOR STATUS) 2
DOOR SENSOR
(NON-SUPERVISED)
EOL (End of Line) Resistor
(1k ohm)
DOOR SENSOR
OR
(SUPERVISED)
DOOR SENSOR
OR
(SUPERVISED)