Gate Access - MyQ LiftMaster CAPAC Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INTRODUCTION

Gate Access

INTRODUCTION
INTRODUCTION
NOTE: The SDA/SLA
Gate input/output shall
not be connected in UL
applications.
PRIMARY RELAY
GATE OPERATOR
NOTE: For UL installations, only
UL 325 Listed gate operators, UL
294 Listed electric door strikes or
UL 294 Listed maglocks may be
connected to relay output 1 or 2.
PRE-INSTALL
PRE-INSTALL
OUTPUT
WIEGAND
PRE-INSTALL
1
2
OUTPUT
GATE
SDA SCL
NO COM NC
NO COM NC
EXIT
AUXILIARY RELAY
Low
Voltage
Power
Supply
Isolation
Relay
NORMALLY OPEN
INSTALL
Not responsible for conflicts between the information listed in
the wiring diagram and the requirements of your local building
INSTALL
codes. The information is for suggested use ONLY. Check your
local codes BEFORE installation.
INPUT
INSTALL
1
2
WIEGAND
INPUT
D1 COM D0
D1 COM D0
1 GND 2
LIGHT
LOAD
LINE
OR
OR
ALARM BYPASS
COMMON
11
NETWORK
ACCESS CONTROL
NETWORK
ACCESS CONTROL
NETWORK
ACCESS CONTROL
POWER
GND 12V-24V
POWER
ETHERNET
STATUS
EOL (End of Line)
Resistor (1k ohm)
GATE OPERATOR
(connect to Aux
Closed Limit switch -
refer to gate operator
manual)
*AUXILIARY RELAY
For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) (provided)
or equivalent
NORMALLY CLOSED
Use 18-22 AWG
COMMON
Power for Maglock
(Not Provided)
DO NOT use the power
supply for the controller
MAGLOCK
For DC Power:
Install a 1N4005
diode or equivalent

Publicité