6.2.1

Fuel qua li ty

The en gi ne is cer ti fied to ope ra te on un lea ded ga so li ne with a
re search oc ta ne ra ting of 91 or hig her (pump oc ta ne ra ting of
86 or hig her).
You may use un leaded gas o line con tain ing no more than 10%
eth a nol (E10) or 5% meth a nol by vol ume.
In ad di tion, meth a nol must con tain cosolvents and cor ro sion
in hib i tors.
Use of fu els with con tent of eth a nol or meth a nol greater than
shown above may cause start ing and/or per for mance prob -
lems.
It may also dam age metal, rub ber, and plas tic parts of the fuel
sys tem.
En gi ne da ma ge or per for man ce pro blems that re sult from
using a fuel with per cen ta ges of et ha nol or me tha nol grea ter
than shown abo ve are not co ver ed un der the War ran ty.
6.2.2
Fuel ca pa ci ty
Ma chi ne
En gi ne type
type
APF 12/40
Honda GX120UT1
6.2.3
[Li ter]
[US gal]
2.5
0.660
57
6. Main ten an ce (HONDA en gi ne)
Fil ling-up with fuel
Be wa re of en gi ne da ma ge.
Us ing poor-qual ity or con tam i nated fuel can cause en -
gine dam age.
Use only fuel that meets the des ig nated spec i fi ca -
tions.
Never use stale or con tam i nated petrol or an
oil/petrol mix ture.
En su re that neit her dirt or wa ter gets into the fuel
tank.
Park the ma chi ne on an even, le vel sur fa ce.
Stop the en gi ne.
Cle an around the fuel fil ler so cket.
Open the fuel filler socket and vi su ally check the fuel level. Re -
fill the tank if the fuel level is low.
Add fuel to the bottomof the maximumfuel level limit of the fuel
tank. Do not over fill. Use un leaded au to mo tive gas o line only.
Wipe up spil led fuel be fo re star ting the en gi ne.
Clo se the tank tight ly.